K68i 300V Relay Tester Secondary Injection Test Equipment

Brand Name:KINGSINE
Certification:CE/ISO6001
Model Number:k68i
Minimum Order Quantity:1 set
Delivery Time:15 working days
Payment Terms:T/T,L/C
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen Guangdong
Address: 6/F, Block 4-CD, TianAn Cyber Park, Futian District, Shenzhen 518048,.China
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

K68i 300V Relay Tester Secondary Injection Test Equipment


AC test


Parameter table structure


QueueParameter nameNumber of bytesDescriptionNote
0nModelType4Model typeThe data is int32 type, and the value is fixed at 1 during the AC test
1gfRange[13]4*13

13channel Amplitude


The data type is a float array, followed by UA, UB, UC, UX, IA, IB, IC, Ua, Ub, Uc, Ia, Ib, Ic, default 0A, 0V
2gfPhase[13]4*1313 channel phaseThe data type is a float array, followed by UA, UB, UC, UX, IA, IB, IC, Ua, Ub, Uc, Ia, Ib, Ic, the default is 0 degree
3gfFrequency[13]4*1313 channel frequencyThe data type is a float array, followed by UA, UB, UC, UX, IA, IB, IC, Ua, Ub, Uc, Ia, Ib, Ic, and the default is 50Hz
4fOutputTime4Output timeThe data is float type, the unit is second, describing the longest time of this output
5nInputBinaryLogic4Binary input logicData is int32 type, value 0 is logical OR, value 1 is logical AND
6nInputBinaryEnable48 channels binary input enableThe data is of int32 type, which defines the binary input 1 to the binary input 8 from low to high bit-coded, in sequence: 1, 2, 3, 4, 5, 6, 7, 8; the value 0 means the binary input is invalid , The value 1 is valid
7fActionTime4Action timeThe data is float type, and the unit is second. It records the action time of this output. The variable is output in the form of test results. When the value is less than 0, it means that the test has no action.

Harmonic test

Parameter construction

QueueParameter nameNumber of bytesDescriptionNote
0nModelType4Model typeThe data is of int32 type, the value is fixed at 2 in the harmonic test
1gfRange[7][21]7*21*4Harmonic amplitude valueThe data type is a float two-dimensional array, 7-phase 21 harmonics, 7-phase is UA, UB, UC, UX, IA, IB, IC in sequence, default 0A, 0V
2gfPhase[7][21]7*21*4Harmonic phaseThe data type is a float two-dimensional array, 7-phase 21 harmonics, 7-phase is UA, UB, UC, UX, IA, IB, IC, and the default is 0 degrees
3fBaseFreqency4Fundamental frequencyData type is float array
4fOutputTime4output timeThe data is float type, the unit is second, describing the longest time of this output
5nInputBinaryLogic4binary input logicData is int32 type, value 0 is logical OR, value 1 is logical AND
6nInputBinaryEnable48 pairs of Binary input enableThe data is of int32 type, which defines the binary input amount 1 to the binary input amount 8 from low to high bit-coded, in sequence: 1, 2, 3, 4, 5, 6, 7, 8; the value 0 means the binary input is invalid , The value 1 is valid
7fActionTime4action timeThe data is of float type and the unit is second. It records the action time of this output. This variable is output in the form of test results. When the value is less than 0, it means that the test has no action.

State Sequencer

Parameter construction

Item No.parameter nameNumber of bytesParameter DescriptionRemark
0nModelType4module typeData type is int32 type, when we use state sequencer module, the value constant as 3
1nStateCount4Number of statesThe data is of type int32
2pStateParam

nStateCount

*

STATE_SIZE

State parameterThe data is a pointer type (single-state parameter table array), and its space size is a multiple of the single-state structure
3nStateIndex4The serial number of the present outputThe data is of int32 type, starting from 0, indicating that the state is currently being output. This variable is output in the form of test results, reflecting the current test output status in real time.

STATE_SIZE is the storage space size of the parameter table of the single state structure.

The structure of the single state parameter table is:

Item No.parameter nameNumber of bytesParameter DescriptionRemark
0gfRange[13]4*1313 phase amplitude valueThe data type is a float array, followed by UA, UB, UC, UX, IA, IB, IC, Ua, Ub, Uc, Ia, Ib, Ic, and the default is 0A,0V
1gfPhase[13]4*1313 phaseThe data type is a float array, followed by UA, UB, UC, UX, IA, IB, IC, Ua, Ub, Uc, Ia, Ib, Ic, and the default is 0 degree
2gfFrequency[13]4*1313 phase frequencyThe data type is a float array, followed by UA, UB, UC, UX, IA, IB, IC, Ua, Ub, Uc, Ia, Ib, Ic, and the default is 50Hz
3fOutputTime4output timeThe data is float type, the unit is second, describing the longest time of this output
4nInputBinaryLogic4Binary input logicData is int32 type, value 0 is logical OR, value 1 is logical AND
5nInputBinaryEnable48 pairs of Binary input enableThe data is of int32 type, which defines the binary input amount 1 to the binary input amount 8 from low to high bit-coded, in sequence: 1, 2, 3, 4, 5, 6, 7, 8; the value 0 means the binary input is invalid , The value 1 is valid
6nTriggerKind4State trigger conditionThe data is of int32 type, the value 0 is time trigger, the value 1 is time plus opening amount trigger, the value 2 is opening amount, the value 3 is button
7nOutputBinaryState4Binary Output initial stateThe data is of int32 type, which defines from the binary output 1 till the binary output 4 by bit-coding from low to high, a single value of 0 indicates that the output is off (no output signal), and the value of 1 indicates that the output is closed
8fOutputBinaryHoldTime4Binary Output Hold TimeThe data is of float type, the unit is second, which represents the holding time of the initial state of the binary output
9fActionTime4action timeThe data is of float type and the unit is second. It records the action time of this output. This variable is output in the form of test results. When the value is less than 0, it means that the test has no action.
China K68i 300V Relay Tester Secondary Injection Test Equipment supplier

K68i 300V Relay Tester Secondary Injection Test Equipment

Inquiry Cart 0