Varian Flat Panel Detector Digital Radiography System With Mobile Photography Bed

Brand Name:Kenida
Certification:CE, ISO13485
Model Number:KDR-200
Minimum Order Quantity:1SET
Delivery Time:In a month
Payment Terms:any payments are received
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen Guangdong China
Address: Room 201,Building H,33 Ping’an Avenue,Xinnan Community,Pinghu street,Longgang District, Shenzhen China 518111
Supplier`s last login times: within 37 hours
Product Details Company Profile
Product Details

Varian Flat Panel Detector Digital Radiography System With Mobile Photography Bed

Features

High frequency
With Mobile photography bed
Varian flat panel detector

Main configuration

NoPart nameTypequantity
    high frequency high voltage generatorYJG30R-A1set
      operating consoleYJO-Ⅳ1set

        X-ray tube

        H10831set

          beam limiting device

          M-381set
            flat panel detector1800R1set
              SLCYJT-Ⅰ1set
                DR rackYJDR-Ⅰ1set
                  Mobile photography bedYJS-Ⅲ1set
                    Acquisition workstation (computer)color screen1set

                      GRID

                      103line1set
                        high voltage cable75kV1pair


                        Main technical parameters

                        NoTechnical parameters
                        1x-ray generator (YJG30R-A)
                        1.1Supply voltage:Three-phase380V±38V
                        *1.2Maximum output power:30kW
                        *1.3Operating frequency≥100kHz
                        1.4Photography tube voltage:Can continuous ,Adjust the step length of 1 kv, the adjusting range is 40 kv ~ 150 kv
                        *1.5Photography tube current:Can step adjustment, adjustment range,10mA~200mA
                        *1.6Load time:adjustable range,2ms~6300ms
                        1.7Current-time:Can step adjustment, adjustment range,0.1mAs~500mAs
                        2Operating console(YJO-Ⅳ)
                        2.1DC12V
                        3X-ray tube (H1083)
                        3.1Maximum working voltage: 125kV
                        *3.2Bi-focus:0.6mm(small focal point)/1.2mm(big focal point)
                        3.3Anode input power:15KW(small focal point);30KW(big focal point)
                        3.4The anode optical Angle:12°
                        *3.5The anode rotation speed:3000rpm
                        3.6Anode heat content:150KHU
                        4.beam limiting device(M-38)
                        4.1Lead door control mode:manual operation
                        4.2Power supply: 24VAC 7A
                        4.3Inherent filtration:1.2mmAL
                        4.4Light flash:30s
                        5Flat panel detector(1800R)
                        *5.1Fluorescent material: Direct growth cesium iodide
                        *5.2Scanning the area size:17×17inch
                        5.3Spatial resolution:≥3.0 lp/mm
                        5.4Analog-digital conversion:16bit
                        6Pixel region:431.8 × 431.8 mm2
                        6.1Pixels array:2816 × 2816
                        6.2Pixel size:154μm
                        6.3Image read time:1~1.5s
                        6.4Time of exposure:Shortest:1 ms; longest:10 s
                        7DR rack
                        7.1Stand column hight:2240mm
                        7.2UC arm to move up and down along the column:700mm~1700mm
                        7.3UC arm along the column rotation range:0°~105°
                        7.4Move up and down detector range:700mm~1700mm control mode:Electric braking force:≥100N
                        7.5X ray tube component movement range:0~800mm±50mm Locking way:power-driven;braking force:≥100N
                        7.6SID distance1000mm~1800mm
                        8Mobile photography bed(YJS-Ⅲ)
                        8.1Panel size bed:length×width× height=2020mm×690mm×680mm
                        8.2Operating mode:manual operation
                        8.3Load-bearing:After under 135 kg weight should be able to work properly
                        Others:
                        9workstation
                        9.1CPU: ≥2.8GHz
                        9.2RAM:≥2GB
                        9.3Disk size:≥500GB
                        9.4Display:≥19″Medical color LCD display
                        10Software function(DRimage processing software)
                        10.1High voltage generator can be equipped with a variety of X-ray tube, the tube of all of the power curve, cooling curve, automatic control by software
                        10.2Has self-check protection function of fault alarm and shutdown in a timely manner
                        10.3Dicom3.0 interfaces for image transmission, query, print, etc
                        10.4With Magellan3 image processing software










                        China Varian Flat Panel Detector Digital Radiography System With Mobile Photography Bed supplier

                        Varian Flat Panel Detector Digital Radiography System With Mobile Photography Bed