Medical 500ma Digital Radiography X Ray System With Varian Flat Panel Detector


Features

High frequency
With Mobile photography bed
Varian flat panel detector

Main configuration

NoPart nameTypequantity
    high frequency high voltage generatorYJG30R-A1set
      operating consoleYJO-Ⅳ1set

        X-ray tube

        H10831set

          beam limiting device

          M-381set
            flat panel detector1800R1set
              SLCYJT-Ⅰ1set
                DR rackYJDR-Ⅰ1set
                  Mobile photography bedYJS-Ⅲ1set
                    Acquisition workstation (computer)color screen1set

                      GRID

                      103line1set
                        high voltage cable75kV1pair


                        Main technical parameters

                        NoTechnical parameters
                        1x-ray generator (YJG30R-A)
                        1.1Supply voltage:Three-phase380V±38V
                        *1.2Maximum output power:30kW
                        *1.3Operating frequency≥100kHz
                        1.4Photography tube voltage:Can continuous ,Adjust the step length of 1 kv, the adjusting range is 40 kv ~ 150 kv
                        *1.5Photography tube current:Can step adjustment, adjustment range,10mA~200mA
                        *1.6Load time:adjustable range,2ms~6300ms
                        1.7Current-time:Can step adjustment, adjustment range,0.1mAs~500mAs
                        2Operating console(YJO-Ⅳ)
                        2.1DC12V
                        3X-ray tube (H1083)
                        3.1Maximum working voltage: 125kV
                        *3.2Bi-focus:0.6mm(small focal point)/1.2mm(big focal point)
                        3.3Anode input power:15KW(small focal point);30KW(big focal point)
                        3.4The anode optical Angle:12°
                        *3.5The anode rotation speed:3000rpm
                        3.6Anode heat content:150KHU
                        4.beam limiting device(M-38)
                        4.1Lead door control mode:manual operation
                        4.2Power supply: 24VAC 7A
                        4.3Inherent filtration:1.2mmAL
                        4.4Light flash:30s
                        5Flat panel detector(1800R)
                        *5.1Fluorescent material: Direct growth cesium iodide
                        *5.2Scanning the area size:17×17inch
                        5.3Spatial resolution:≥3.0 lp/mm
                        5.4Analog-digital conversion:16bit
                        6Pixel region:431.8 × 431.8 mm2
                        6.1Pixels array:2816 × 2816
                        6.2Pixel size:154μm
                        6.3Image read time:1~1.5s
                        6.4Time of exposure:Shortest:1 ms; longest:10 s
                        7DR rack
                        7.1Stand column hight:2240mm
                        7.2UC arm to move up and down along the column:700mm~1700mm
                        7.3UC arm along the column rotation range:0°~105°
                        7.4Move up and down detector range:700mm~1700mm control mode:Electric braking force:≥100N
                        7.5X ray tube component movement range:0~800mm±50mm Locking way:power-driven;braking force:≥100N
                        7.6SID distance1000mm~1800mm
                        8Mobile photography bed(YJS-Ⅲ)
                        8.1Panel size bed:length×width× height=2020mm×690mm×680mm
                        8.2Operating mode:manual operation
                        8.3Load-bearing:After under 135 kg weight should be able to work properly
                        Others:
                        9workstation
                        9.1CPU: ≥2.8GHz
                        9.2RAM:≥2GB
                        9.3Disk size:≥500GB
                        9.4Display:≥19″Medical color LCD display
                        10Software function(DRimage processing software)
                        10.1High voltage generator can be equipped with a variety of X-ray tube, the tube of all of the power curve, cooling curve, automatic control by software
                        10.2Has self-check protection function of fault alarm and shutdown in a timely manner
                        10.3Dicom3.0 interfaces for image transmission, query, print, etc
                        10.4With Magellan3 image processing software