Overview
TCS thermal flow switch for hydropower station water cooling
system, lubrication system flow monitoring and control and the
development of an electronic product. The product is based on the
principle of thermal diffusion, improve the traditional mechanical
products with complicated structure, setting defects easily drift
and small flow state is not stable, and can be applied to various
medium traffic monitoring applications.
Two, technical parameters
Working medium: oil, water and gas
Scope of application: oil 0-10m/s; water 0-5m/s; gas 0-50m/s
Response time: typical 2S, maximum 8s
Repeatability: + 1% set point range
Suitable pipe diameter: DN15-DN300
Operating voltage: AC24V/DC24V; AC220V/DC24V.
Current consumption: less than 65mA
Voltage rating: 10Mpa
Medium temperature range: -25 DEG C -80 C
Connection mode: G1/2 (welding seat, welding seat internal thread
G1/2)
Enclosure protection: stainless steel case with IP67 protection
Relay output:
TCS-K1:1 group alarm contacts; contact capacity: 2A/AC220V
TCS-K2:2 group alarm contacts; contact capacity: 2A/AC220V