Add to Cart
Dust collector applications , in particular for reverse pulse jet filter cleaning including bag filters , ceramic filters , and sintered metal fibre filters.
Features
1. Specially designed for reverse jet-type dust collector systems
2. High flow Cv’s to 140 for effective bag cleaning
3. High cycle life.
4. Fast opening/closing
Simple maintenance
Before condcting any maintenance activity on the system ensure that
componnents are fully isolated from pressure and power
supplies .Pressure and power should not be reapplied until the
valve has been fully assembled.Diaphragm and pilot inspection
should be conducted annually.
Installation
For your safety do not pressurise system until all valves and pipes
are fully secured. Do not attempt to remove a
fitted valve while system is under pressure.
1. Prepare supply and blowtube pipes* to suit valve type and
specification.
2. Ensure tank and pipes are free from dirt, rust or other
particulate.installing valves underneath the tank.
3. Apply moderate pressure to system and check for installation
leaks.
4. Mount valves to inlet pipes (or flanges, tighten bolts to 10Nm)
and blowtube tovalves, ensuring no excess thread sealant can enter
the valve itself. Ensure blowtube is fully inserted into the valve
outlet.
5. Tanks and pipes must be independently restrained from FS and DD
valves.
6. Ensure supply air is clean and dry.
7. Connect RCAC pilot port to remote pilot valve, or install
MIP/3DS screw in pilot valve.
8. Fully pressurise system.
9. Test fire and listen for proper actuation and crisp pulse noise.
Construction | |
Body | Aluminum (Diecast) |
Washer | SS 304 |
Armature | SS 430FR |
Core and Plugnut | Stainless steel |
Core Spring | SS 304 |
Sealing & disc | NBR(nitrile/buna-n) |
Screws | SS302 |
Diaphragm | PA-6(Standard), fluororubber |
Shading coil | Copper |
Connector | DIN43650A |
Voltage | DC: 24V, AC: 24V, 48V, 110V, 230V |
Working Temperature | -20 to +85℃ Nitrile seals -29 to +232℃ fluororubber seals |
Protection Class | IP65 |
Coil Insulation Class | F |
Working Pressure | 0.35-0.85Mpa |
Recommended on time range | 50-500ms |
Recommended time between pulses | 1 minute or Less |
Drawings:
CA/RCA20T