X-Ray Directional Radiographic Inspection Machine Ceramic Tube Penetrant 50mm

Brand Name:HUATEC
Certification:ISO, CE, GOST
Model Number:XXG-3205
Minimum Order Quantity:1pcs
Delivery Time:1-4days
Payment Terms:T/T, Paypal, Western Union
Contact Now

Add to Cart

Verified Supplier
Location: Beijing Beijing
Address: 7th Floor, Chengyuan Building B, the Mid. Road of Jiancaicheng Haidian Dist.BeiJing,CHINA 100096
Supplier`s last login times: within 48 hours
Product Details Company Profile
Product Details

320KV Ceramic tube penetrant 40mm Directional Radiographic inspection machine


Main technical parameters


ITEM

XXG3205
Max Penetration thickness Steel (A3)55mm
Focal Distance600mm
Exposure Time5min
Film TypeAgfa D7

Double lead foil Intensifying screen

0.03
Darkroom Disposal20±2℃
Development5minutes
Blackness1.5
InputVoltage (V)220V±10% 50―60Hz
Capacity (KVA)3.2
OutputTube voltage (KVP)170-320Kv
Tube current (mA)5
Stability±1%

X-RAY

Tube

Focus mm22.5×2.5
Radiation Angle40±5°
Sensitivityk≤1.8%
Operation ModeIntermittent operation, Radiating time to cooling time is 1:1

X-Ray

Controller

Dimension350×290×160
Weight11kg
Circuit StructureMicro-computer control ,Modular structure,Voice prompt

X-RAY

Generator

CoolingForce air cooling
InsulationSF6 Gas Insulation
Working Pressure0.35Mpa-0.45Mpa
Dimension335×335×700
Weight (kg)43kg
Working Temperature-10℃―+40℃

Standard Delivery

Directional glass X-ray tube1 Pcs
Generator1 Set 
High voltage joins cable1 Pcs25 Meters
Controller1 Set 
Power cable1 Pcs10 Meters
Grounding cable1 Pcs5 Meters
Accessories1 Set 
(Including: alarm lamp,1 Pcs; lead letter, 1 box; Film dark cassettes 5 pcs; intensifying screen 5 pcs; Wire penetrameter (IQI) 1 set; fuse1 pc)



System Installation

1.Check and count all goods to be received per the packing list. And then check the quality of the parts for damage,lost and mistake.

2.Keep the controller in a flat,dry and dustless place, switch off the power and connect the power cable.

(Note:

The power supply of the unit is single phase 220V±10% 50-60HZ)

3.If necessary,one end of earth wire can be connected to the earth terminal of the controller and the other end to the special grounding wire.

4.Connect controller to x-ray generator by special 9 cores cable,and form better contact.

5.Check the gas pressure gauge on x-ray generator and make sure it range from 0.35Mpa to 0.45Mpa.If not,the unit is not allowed to turn on so as to avoid any damage to the x-ray generator.


Working Principle

This machine is composed of intelligent controller-ray generator, power cable and connecting cable.

1.The controller will consist of the following sections:

Front Panel: LED display, status and failure indicator, touch keyboards (see the introduction of control panel)

Side Panel: power cable socket and connecting cable socket, power switch,key switch, fuse socket, warning lamp and wire connecting terminal of door-machine interlock.

Internal Circuit: power circuit, rectifying circuit, filter circuit, inverter circuit, control circuit and other circuited.

2.The x-ray generator will consist of the following sections:

X-ray tube, High voltage transformer, Temperature relay, Gas pressure gauge and Cooling fan etc.

3.The schematic diagram of the complete machine:

Optional accessories:

Testing platform, IQI/wire penetrameter, lead letter/digits, lead tape, Cassette, lead screen, personal dosimeter, film viewer, densitometer, film developer, dark room light, RT calibration block etc.


China X-Ray Directional Radiographic Inspection Machine Ceramic Tube Penetrant 50mm supplier

X-Ray Directional Radiographic Inspection Machine Ceramic Tube Penetrant 50mm

Inquiry Cart 0