Add to Cart
110V Crack testing equipment Magnetic Particle Testing For Surface
Crack Testing HCDX-230
Defect examples: Defect location:
Inclusions Seams Surface and subsurface Ideal for: Fatigue cracks
Shrink cracks Tears Laps Field testing pot inspections
Welding slag Grinding cracks In-service inspections
Quenching cracks Demanding environments
Weld inspection
The HCDX-230 series is a durable, high-strength AC, AC/DC, DC
magnetic yoke designed to detect surface and sub-surface
indications in the most rugged applications.
Featuring sealed chemical-resistant construction, articulating legs
to contour to any part shape and robust strain-relieved twelve-foot
cord for field use, the HCDX-230 is ideal for inspection of welds
and other remote testing.
Solid-state controls allow the operator to use AC magnetic fields
for surface indications or DC magnetic fields for sub-surface
indications to meet all inspection needs.
The charging type magnetic particle flaw detector has the
characteristics of compact structure, reasonable layout, small
size, light weight and convenient portability. The flaw detector
can be used directly in alternating current, and can also be used
for AC magnetization power supply (AC battery pack) and DC
magnetized power supply (DC-AC inverter battery pack), which is
efficient and portable. It is suitable for hull weld inspection,
high altitude steel structure weld detection and pressure vessel
internal operation. This instrument is suitable for steel structure
parts of power, metallurgy, petrochemical, machinery and other
industries, such as boiler, pressure vessel, pressure pipe, ship
body weld and welding structure of various types of ferromagnetic
material surface and magnetic particle flaw detection of near
surface defect.
This instrument conforms to the standard requirements of
JB/T7411-2012, ASME BPVC,ASTM E709,ASTM E1444,ASTM
E3024."electromagnetic yoke flaw detector technical condition".
Product features
Sealed, durable construction
Chemical and abrasion resistant
AC and DC operation options for surface and sub-surface inspection
Exceeds ASTM lifting specifications
The three modes of power supply can be freely chosen:
There are places directly connected to AC power supply, which can
be directly connected with AC power supply.
It is possible to use AC magnetized power supply (DC-AC inverter
battery pack) to supply AC power without any direct insertion to AC
power supply.
The DC magnetizing power supply (DC battery pack) can be used to
realize the DC magnetization function.
AC magnetizing power supply (DC-AC inverter battery pack) has the
functions of voltage regulation, overcharge, over current and over
discharge.
When the lifting force is not enough, the power is automatically
cut off to ensure the sensitivity of flaw detection.
The power display function can display the current battery power,
and has the function of sound and light alarm.
Built in microcomputer chip to stabilize output voltage and ensure
detection sensitivity.
Adjustable magnetization
Special working waist bag can carry battery pack, magnetic
suspension, contrast agent, yoke probe, etc.
Technical parameter
Working temperature: -10 ~ +40 C
Storage temperature: -20 ~ 50 C
Relative humidity: <80% non condensation
Work temperature rise: <18 C
Temporary load rate: >50%
Sensitivity: A1 standard test piece 15/50 groove clearly displayed.
AC minimum power hoisting power: >4.5kg (44N)
DC minimum power hoisting power: >18.1kg (177N)
Model guide
Model | HCDX-230 | HCDX-230 | HCDX-230 | HCDX-230E | |||||
Power supply | 110V/220V 50/60Hz-12V | 110V/220V 50/60Hz 12/V | 110V/220V 50/60Hz | 110V/220V 50/60Hz | |||||
Charging power | 110V/220V 50/60Hz-12V | 110V/220V 50/60Hz 12V | / | / | |||||
Battery | YD-2 Inverter battery | Rechargeable battery | / | / | |||||
Working current | AC 3A | 3A | 3A | 3A(AC-DC Switching Converters) | |||||
Charging duration | 3h | 3h | / | / | |||||
Battery duration | 6h-8h | 6h-8h | / | / | |||||
Battery size | 60×96×170mm | 60×96×170mm | |||||||
Aperture time | 3 ~ 5 seconds on / 3 to 5 seconds off | ||||||||
Magnetizing length | 50-200mm | 50-200mm | 50-200mm | 50-240mm | |||||
Lift | AC | ≥6㎏ | / | ≥4.8㎏ | ≥5.5㎏ | ||||
DC | ≥18.5㎏ | ≥18.5㎏ | / | ≥25㎏ | |||||
Weight | Probe | 3.2㎏ | 3.2㎏ | 3.2㎏ | 3.5㎏ | ||||
Battery | 2.9㎏ | 2.9㎏ | / | / | |||||
Figure | Probe | 208×48×148 | 208×48×148 | 208×48×148 | 210×60×260 | ||||
Battery | 170×96x60 | 170×96x60 | / | / | |||||
Standard configuration:
HCDX-230 DC-AC Inverter AC yoke kit
Magnetic powder flaw detector host 1
Power line 1
Rechargeable Inverter DC battery pack (DC magnetized power supply
110V/220V 50/60Hz) 1
DC power backpack 1
Power adapter 1
DC output connection line 1
Instrument box 1
Certificate 1
Manual 1
HCDX-230 DC
Magnetic powder flaw detector host 1
Power line 1
Rechargeable DC battery pack (DC magnetized power supply) 1
DC power backpack 1
Power adapter 1
DC output connection line 1
Instrument box 1
Certificate 1
Manual 1
HCDX-230 AC
Magnetic powder flaw detector host 1
Power line 1
Instrument box 1
Certificate 1
Manual 1
HCDX-230E AC-DC switch
Magnetic powder flaw detector host 1
Power line 1
Instrument box 1
3A (AC-DC Switching Converters)
Certificate 1
Manual 1