Add to Cart
High Sensitivity Stocks 5000pcs OMRON MEMS Thermal Sensors D6T-1A-02 For Contactless Measurement
(Unit: mm)
Item | D6T-44L-06/06H | D6T-8L-09/09H | D6T-1A-01 | D6T-1A-02 | D6T-32L-01A |
---|---|---|---|---|---|
Power supply voltage | 4.5 to 5.5 VDC | ||||
Storage temperature range* | −10 to 60°C | −20 to 80°C | −40 to 80°C | −20 to 80°C | |
Operating temperature range* | 0 to 50°C | 0 to 60°C | −10 to 70°C | ||
Storage humidity range* | 85% max. | 95% max. | |||
Operating humidity range* | 20% to 85% | 20% to 95% |
Item | D6T-44L-06/06H | D6T-8L-09/09H | D6T-1A-01 | D6T-1A-02 | D6T-32L-01A | |
---|---|---|---|---|---|---|
View angle*¹ | X direction | 44.2° | 54.5° | 58.0° | 26.5° | 90° |
Y direction | 45.7° | 5.5° | ||||
Object temperature output accuracy*² | Accuracy 1 | ±1.5°C max. / Measurement conditions: Vcc = 5.0 V (1) Tx = 25°C, Ta = 25°C (2) Tx = 45°C, Ta = 25°C (3) Tx = 45°C, Ta = 45°C | Within ±3.0°C / Measurement conditions: Vcc = 5.0 V Tx = 25°C, Ta = 25°C Central 16-pixel area | |||
Accuracy 2 | ±3.0°C max. / Measurement conditions: Vcc = 5.0 V (4) Tx = 25°C, Ta = 45°C | Within ±5.0°C / Measurement conditions: Vcc = 5.0 V Tx = 80°C, Ta = 25°C Central 16-pixel area | ||||
Current consumption | 5 mA typical | 3.5 mA typical | 19 mA typical |
Item | D6T-44L-06/06H | D6T-8L-09/09H | D6T-1A-01 | D6T-1A-02 | D6T-32L-01A |
---|---|---|---|---|---|
Object temperature detection range*2 | 5 to 50°C/5 to 200°C | 5 to 50°C | −40 to 80°C | 0 to 200°C | |
Ambient temperature detection range*2 | 5 to 45°C | 0 to 80°C | |||
Output specifications | Digital values that correspond to the object temperature (Tx) and
reference temperature (Ta) are output from a serial communications port. | ||||
Output form | Binary code (10 times the detected temperature (°C)) | ||||
Communications form | I2C compliant | ||||
Temperature resolution (NETD)*3 | 0.06°C | 0.03°C | 0.02°C | 0.06°C | 0.33°C *4 |
Object Temperature Detection Range
Connections
Thermal Sensor Configuration Diagram
< D6T-8L-09/09H >
Terminal Arrangement
Name | Terminal | Function | Remarks |
---|---|---|---|
GND | 1 | Ground | – |
VCC | 2 | Positive power supply voltage input | – |
SDA | 3 | Serial data I/O line | Connect the open-drain SDA terminal to a pull-up resistor. |
SCL | 4 | Serial clock input | Connect the open-drain SCL terminal to a pull-up resistor. |
Field of View Characteristics
* Definition of view angle: Using the maximum Sensor output as a
reference, the angular range where the Sensor output is 50% or
higher when the angle of the Sensor is changed is defined as the