275V Type 1+2 Surge Protector , Ac Spd 4 Pole Remote Alarm Interface

Brand Name:Uchi
Certification:CE / SGS / ISO9001
Model Number:OBV5-B60
Minimum Order Quantity:200 piece
Delivery Time:5-15 days after payment
Payment Terms:T/T, L/C, Western Union
Contact Now

Add to Cart

Verified Supplier
Location: Dongguan Guangdong China
Address: Room 810, Unit 2, Building 5, Huixing Commercial Center, Dongsheng Road No.1, Zhongshan Dong, Shilong Town Dongguan, GUANGDONG, 523326 CN
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

AC 275/320/385/440V Type 1+2 Surge Protection Device With Class 3+4

OBV5-B60 series

Class B+C surge protection devices (Type I+II Surge Protectors) are designed by combining Class B (10/350us) and Class C (8/20μs) lightning and switching surge to be used in the equipotential connection of LPZ 0 and LPZ 2 zone.


Class B+C surge protector is perfect for any kind of building being it residential, commercial, industrial and so on, these devices work as a complete protection device. In addition to this, you can also install transient voltage surge suppressor in those buildings, which get power via an overhead line resulting direct or partial lightning currents.


The combination lightning current and surge arrestors OBV5-B60 meet the type 1+2 requirement class according to IEC 61643-11. These devices protect low-voltage consumer systems from overvoltages of all types and are available in single-pole to four-pole versions. The use of high-performance varistors permits a rapid response time and a low protection level, without any line follow current. If circumstances are uncertain and there is a risk of fire from an overload, the internal cut-off unit disconnects the arrestor from the mains if necessary.


1.High energy surge protection

2.Remote alarm interface

3.Failure detection indicator

4.Standard modular installation

G2060MT: The power line blocks the total power disribution cabinet of the nuildings that are embedded in the ground

A distribution box with an outside entry and exit line in the building

Outdoor distribution cabinet/distribution box.


Technical Parameters


Model: OBV5-B60
Maximum continuous voltage ACUcV275/320/385/440
SPD to EN 61643-11Type 1+2
SPD to IEC 61643-1class I+II
Lightning impulse current (10/350µs)IimpkA12,5
Nominal discharge current (8/20µs)InkA30
Maximum discharge current (8/20µs)ImaxkA60
Voltage protection levelUpkV< 1,5/1,8/2,0/2,2
Response timetAns< 25
Maximum back-up fuseA125
Temperature rangeϑ-40℃~+85℃
Protection ratingIP 20
Max. cable cross-section flexible (fine-wire)mm²25
Max. cable cross-section rigid (single wire/multi-wire)mm²35

Feature:


1,Protect electric system and on-loading electrical apparatus from thunder and instantaneous over-voltage.
2,Protect transmission of Ethernet signals with 48V DC / 34V AC power supply circuits against
lightning induced surges.
3,Enhanced surge protection.
4,For mounting on 35mm DIN rails acc. to EN 60715
5,It can effectively ensure the equipments work properly

Technology SPD parameter(Note:According to user requirement ,can be customized Uc=140V,440V,550V,voltage range of range of the SPD):


Type No.Rated Voltage(V) UnContinuous Voltage Uc(V~)Standard Discharge Current In(KA)

Max Discharge Current

Imax(KA)

Protection Level(KA~)Response Time(ns)
DGM1(2)-D5220/380

275/320

385/420

5101.2≤25
DGM1(2)-D101021.6
DGM1(2)-C2020401.8
DGM13-B303060.2.2
DGM3(4)-B4010802.4
DGM(4)-B60601002.8
DGM-N-PE220/25540/6060/801.2≤100