OBV5-C40-PV
PV Heavy Duty SPDs,Type 1+2 of surge protective devices comprises a
complete range of compact protectors for common and differential
mode protection against transient overvoltages at the DC-side of
photovoltaic power plants or TNC.
Prewired modular complete unit for use in photovoltaic systems
consisting of a base part and plug-in protection modules combined
disconnection and short-circuiting device with safe electrical
isolation in the protection module prevents fire damage resulting
from d.c. switching arcs (patented SCI principle)
Tried and tested fault-resistant Y circuit of the OBV5-C40-PV
prevents damage to the surge protective device in case of
insulation faults in the generator circuitIntegrated d.c. fuse
allows safe replacement of protection modules without arc
formation.
Technical Parameters
Model: OBV5-C40-PV | ||||||
Network voltage | 500Vdc | 600Vdc | 800Vdc | 900Vdc | 1000 Vdc | |
Max. operating voltage Uc | 530Vdc | 630Vdc | 840Vdc | 950Vdc | 1060 Vdc | |
Nominal discharge current ln | 20kA | |||||
Max. discharge current lmax | 40kA | |||||
Protection level (at In) Up | 1.8kV | 2.5kV | 2.8kV | 3.0kV | 3.2kV | |
Disconnector | ||||||
Thermal Disconnector | Internal | |||||
Mechanical characteristics | ||||||
Connection | by screw terminals: 4-25 mm2 | |||||
Disconnection indicator | 1 mechanical indicator by pole | |||||
Mounting | symmetrical rail 35 mm | |||||
Operating temperature | -40/+85°C | |||||
Protection class | IP20 | |||||
Standards compliance | ||||||
NF EN 61643-11 France | Parafoudre Basse Tension - Essais Classe II | |||||
IEC 61643-1 International | Low Voltage SPD - Test Class II | |||||
EN 61643-11 Europe | Parafoudre Basse Tension - Essais Classe II |
Feature&Benefits
1,Protect electric system and on-loading electrical apparatus from
thunder and instantaneous over-voltage.
2,Protect transmission of Ethernet signals with 48V DC / 34V AC
power supply circuits against
lightning induced surges.
3,Enhanced surge protection.
4,For mounting on 35mm DIN rails acc. to EN 60715.
5,It can effectively ensure the equipments work properly.
·Easy installation or retrofit.
·Din-rail mountable.
·Fail-safe /self-protected designRemote indicator (optional) with
3pin NO/NC contact.
·IP20 finger-safe designVisual indicator.
·Small foot print.
Application
●AC/DC distribution
●Power supplies
●Industrial automation
●Telecommunications
●Motor controls systems
●PLC applications
●Power transfer equipment
●HVAC applications
● AC drives
●UPS systems
●Security systems
●IT/Data centers
Others
Technology SPD parameter(Note:According to user requirement ,can be
customized Uc=140V,440V,550V,voltage range of range of the SPD):
Type No. | Rated Voltage(V) Un | Continuous Voltage Uc(V~) | Standard Discharge Current In(KA) | Max Discharge Current | Protection Level(KA~) | Response Time(ns) |
DGM1(2)-D5 | 220/380 | 275/320 | 5 | 10 | 1.2 | ≤25 |
DGM1(2)-D10 | 10 | 2 | 1.6 | |||
DGM1(2)-C20 | 20 | 40 | 1.8 | |||
DGM13-B30 | 30 | 60 | .2.2 | |||
DGM3(4)-B40 | 10 | 80 | 2.4 | |||
DGM(4)-B60 | 60 | 100 | 2.8 | |||
DGM-N-PE | 220/255 | 40/60 | 60/80 | 1.2 | ≤100 |
Transient voltage surgesin lv power lines
Transient overvoltages are voltage surges that can reach tens
ofkilovolts with a duration of the order of microseconds.Despite
theirshort duration, the high energy content can cause serious
problemsto equipment connected to the line, from premature aging to
destruction, causing disruptions to service and financial
loss.Thistype of surge can have various different causes, including
atmospheric lightning directly striking the external
protection(lightning rods) on a building or transmission line or
the associatedinduction of electromagnetic fields on metallic
conductors.
Outdoor and longer lines are the most exposed to these fields,which
often receive high levels of induction.
It is also common for non-weather phenomena, such as transformer
centre switching or the disconnection of motors orother inductive
loads to cause voltage spikes in adjacent lines.
Importance of theground connection
Overvoltage protectors (SPD) divert excess energy toground, so
limiting the peak voltage to an acceptablevalue for connected
electrical equipment.
A ground connection in adequate condition is, therefore,a key
aspect for effective protection against overvoltages.Monitoring
ground connection condition guaranteesproper operation of surge
protection devices.
Q: Can I get some samples?
A: Yes, Sample orders welcomed.
Q: Can I use my own Logo or design on goods?
A: Yes, Customized logo and design on mass production are
available.
Q:What is the delivery time?
A: 3 days for samples, 7-15 days for mass production.
Q: What is the payment term?
A: T/T, L/C at sight, West union , Paypal, etc.