Prewired modular complete unit for use in photovoltaic systems consisting of a base part and plug-in protection modules
Combined disconnection and short-circuiting device with safe electrical isolation in the protection module prevents fire damage resulting from d.c. switching arcs (patented SCI principle)
Tried and tested fault-resistant Y circuit of the OBV6-C40-PV prevents damage to the surge protective device in case of insulation faults in the generator circuit.
Integrated d.c. fuse allows safe replacement of protection modules without arc formation.
Technical Parameters
Model: OBV5-C40-PV | ||||||
Network voltage | 500Vdc | 600Vdc | 800Vdc | 900Vdc | 1000 Vdc | |
Max. operating voltage Uc | 530Vdc | 630Vdc | 840Vdc | 950Vdc | 1060 Vdc | |
Nominal discharge current ln | 20kA | |||||
Max. discharge current lmax | 40kA | |||||
Protection level (at In) Up | 1.8kV | 2.5kV | 2.8kV | 3.0kV | 3.2kV | |
Disconnector | ||||||
Thermal Disconnector | Internal | |||||
Mechanical characteristics | ||||||
Connection | by screw terminals: 4-25 mm2 | |||||
Disconnection indicator | 1 mechanical indicator by pole | |||||
Mounting | symmetrical rail 35 mm | |||||
Operating temperature | -40/+85°C | |||||
Protection class | IP20 | |||||
Standards compliance | ||||||
NF EN 61643-11 France | Parafoudre Basse Tension - Essais Classe II | |||||
IEC 61643-1 International | Low Voltage SPD - Test Class II | |||||
EN 61643-11 Europe | Parafoudre Basse Tension - Essais Classe II |
Feature&Benefits
-Easy installation or retrofit
-Din-rail mountable
-Fail-safe /self-protected designRemote indicator (optional) with
3pin NO/NC contact
-IP20 finger-safe designVisual indicator
-Small foot print
Note: The system lightning protection does not guarantee that the
equipment will not be 100% damaged by lightning; the power system
must be multi-level lightning protection;
The complete lightning protection system includes external
lightning protection and internal lightning protection. External
lightning protection refers to: lightning receptors, down
conductors, and grounding bodies, which are mainly used to defend
against direct lightning strikes. Internal lightning protection
includes: shielding, reasonable wiring, safe distance,
equipotential connection, overvoltage protection, etc., mainly used
to prevent lightning induction, ground potential counterattack,
lightning wave intrusion, etc.
Application
●AC/DC distribution
●Power supplies
●Industrial automation
●Telecommunications
●Motor controls systems
●PLC applications
●Power transfer equipment
●HVAC applications
● AC drives
●UPS systems
●Security systems
●IT/Data centers
Tip: Lightning protection is probabilistic protection, and we cannot provide 100% protection.
First, lightning discharge itself has a certain degree of
randomness, and lightning parameters have certain statistical
properties, which determines that all protective measures based on
these statistical characteristics of lightning parameters cannot
provide 100% protection. Such as: direct lightning
protection-shielding characteristics; lightning current amplitude,
waveform, etc. have statistical properties;
Second, the lightning protection equipment cannot prevent the
formation of lightning flashes;
Third, lightning protection devices cannot ideally eliminate all
interference voltages/currents. The fundamental purpose of taking
protective measures is to ensure that most of the energy caused by
interference does not spread to the vulnerable parts of the device
and the staff.
Finally, the cost of protection against high-level surges with a
small probability of occurrence has risen sharply.
One easy solution
With this solution, many cells in power plant and residential
application have been protected. If you don't protect your cells,
in case of several big surges, your cells will be completely
damaged and in case of many small surges without visual damages for
you, your effciency will go down over the years. You should use a
surge protection to have a better return on investment. Class C
surge protection for photovoltaic
Discharge current In: 20kA / Imax: 40kA
Plug-in modules
Remote signal option
IEC 61643-1 compliance
OBV5-C40-PV DC series are Class C Surge Protection Devices, they
designed to protect against lightning surge voltages in
photovoltaic power supply networks. These units must be installed
in parallel on the DC networks to be protected and provide common
and differential modes protection. The OBV5-C40-PV DC series are
availa-ble for the main operating voltages in photovoltaic : 500,
600,800,900 and 1000 Vdc. The use of Class C Surge Protection
Devices are recommended at both ends of the DC power supply line
(solar panel side and inverter/converter side), especially if the
line routing is external and long. The electrical diagram of the
OBV5-C40-PV DC series are based on high energy MOVs equipped with
specific thermal disconnectors and related failure indicators. A
remote signal feature is also available
The OBV5-C40-PV DC series are made with plug-in modules to allow a
fast and easy maintenance in case of fa-ilure (disconnection from
the DC network).
Others
Technology SPD parameter(Note:According to user requirement ,can be
customized Uc=140V,440V,550V,voltage range of range of the SPD):
Type No. | Rated Voltage(V) Un | Continuous Voltage Uc(V~) | Standard Discharge Current In(KA) | Max Discharge Current | Protection Level(KA~) | Response Time(ns) |
DGM1(2)-D5 | 220/380 | 275/320 | 5 | 10 | 1.2 | ≤25 |
DGM1(2)-D10 | 10 | 2 | 1.6 | |||
DGM1(2)-C20 | 20 | 40 | 1.8 | |||
DGM13-B30 | 30 | 60 | .2.2 | |||
DGM3(4)-B40 | 10 | 80 | 2.4 | |||
DGM(4)-B60 | 60 | 100 | 2.8 | |||
DGM-N-PE | 220/255 | 40/60 | 60/80 | 1.2 | ≤100 |
Importance of theground connection
Overvoltage protectors (SPD) divert excess energy toground, so
limiting the peak voltage to an acceptablevalue for connected
electrical equipment.
A ground connection in adequate condition is, therefore,a key
aspect for effective protection against overvoltages.Monitoring
ground connection condition guaranteesproper operation of surge
protection devices.
Q: Can I get some samples?
A: Yes, Sample orders welcomed.
Q: Can I use my own Logo or design on goods?
A: Yes, Customized logo and design on mass production are
available.
Q:What is the delivery time?
A: 3 days for samples, 7-15 days for mass production.
Q: What is the payment term?
A: T/T, L/C at sight, West union , Paypal, etc.