Add to Cart
OBVT-BNC
Coaxial BNC Video Surge Protectors are designed to guard computer network system that includes the monitoring system of security system, coaxial signal transmission and close -circuit TV, satellite communication system.
OBVT is the series of devices for discharging transient overvoltages induced in coaxial lines. In accordance with IEC 61643-21. Coaxial format.
Suitable for the protection of radiofrequency transmission and
reception equipment. By their nature, they are highly exposed to
induced transient overvoltages (surges) associated with
meteorological activity.
For BNC, F, N, TNC connectors.
Ideal for the protection of transmission and reception systems such
as TV and radio antennas, closed circuit TV (CCTV), alarms, etc.
Technical Parameters
OBVT-BNC | OBVT-N | OBVT-F | |
Nominal Operating Voltage (Un) | DC5V | ||
Maximum Continuous Operating Voltage (Uc) | DC8V | ||
Nominal Discharge Current In (8/20µs)kA | 10kA | ||
Maximum discharge current Imax (8/20µs)kA | 20kA | ||
Voltage protection level (Up) | <120V | ||
Interface | BNC | N | F |
Bandwidth (MHz) | 10-40 | ||
Response time tA | <10ns |
Feature&Benefits
-Easy installation
-Fail-safe /self-protected design
-Very fast response
-Hybrid GDT and Diode
-TechnologyLong distance transmission
-Good transmission effect
-Strong anti-interference
-complies lEC 61643-21 standard
Application
●HVAC applications
● AC drives
●UPS systems
●Security systems
●IT/Data centers
●AC/DC distribution
●Power supplies
●Industrial automation
●Telecommunications
●Motor controls systems
●PLC applications
●Power transfer equipment
Others
Technology SPD parameter(Note:According to user requirement ,can be
customized Uc=140V,440V,550V,voltage range of range of the SPD):
Type No. | Rated Voltage(V) Un | Continuous Voltage Uc(V~) | Standard Discharge Current In(KA) | Max Discharge Current | Protection Level(KA~) | Response Time(ns) |
DGM1(2)-D5 | 220/380 | 275/320 | 5 | 10 | 1.2 | ≤25 |
DGM1(2)-D10 | 10 | 2 | 1.6 | |||
DGM1(2)-C20 | 20 | 40 | 1.8 | |||
DGM13-B30 | 30 | 60 | .2.2 | |||
DGM3(4)-B40 | 10 | 80 | 2.4 | |||
DGM(4)-B60 | 60 | 100 | 2.8 | |||
DGM-N-PE | 220/255 | 40/60 | 60/80 | 1.2 | ≤100 |
How to choose a suitable power arrester:
When choosing lightning arresters to protect different types of equipment in an area, the following factors should be considered comprehensively:
●The intensity of thunderstorms in the area, the number of days of thunderstorms and the parameters of the maximum discharge current and the probability of occurrence;
●The value of the protected equipment;
●The level of impact resistance of the protected equipment;
●The social importance of protected equipment;
●Determine the power surge arrester with different protection voltage UP and discharge current;
The main parameters of the lightning arrester
(1) Nominal voltage Un: The additional voltage of the maintained
system is consistent with it. In the information technology system,
this parameter indicates the type of maintainer that should be
selected, and it indicates the effective value of the communication
or DC voltage.
(2 Maximum continuous voltage Uc: The maximum effective voltage
value that can be permanently applied to the designated end of the
lightning protector without causing changes in the characteristics
of the lightning protector.
(3) Nominal discharge current In: The lightning protection device
is not damaged by applying a standard lightning wave with a
waveform of 8/20μs to the lightning protection device for 10 times.
(4) Maximum discharge current Imax: The peak value of the maximum
impulse current that the lightning protector can withstand when a
standard lightning wave with a waveform of 8/20μs is applied to the
lightning protector for one impact.
(5) Voltage protection level Up: The voltage protection level of
the lightning arrester in the case of In.
When selecting the type, the Uc of the lightning arrester must meet
the system voltage, the flow rate must meet the use requirements,
and the protection level must be lower than the equipment withstand
voltage.
Q: Can I get some samples?
A: Yes, Sample orders welcomed.
Q: Can I use my own Logo or design on goods?
A: Yes, Customized logo and design on mass production are
available.
Q:What is the delivery time?
A: 3 days for samples, 7-15 days for mass production.
Q: What is the payment term?
A: T/T, L/C at sight, West union , Paypal, etc.