UL94-V0 flame retardant Surge Backup Protector with 60KA discharge current capability
Surge Special Circuit Breaker (SCB) Product advantage:
Power frequency cut off capacity up to 10KA(8/20us)
Imax 60ka without misoperation
Integral housing, can reduce the volume, increase the flow capacity
With T reset key,electrify can be cut off manually
The ability to withstand the impact of current is strong, no wrong action;
Power frequency current through more than 3A trip;
Running short circuit current breaking ability is strong;
35mm guide rail installation;
Product Parameter
Style | YCSCB-60/B-OV |
Short-circuit breaking capacity(Ics) | 10kA |
Rated operational voltage(Ue) | 230V |
Rated insulation voltage (Ui) | 400VAC |
Impulse withstand current (Iemax) | 60kA(8/20us) |
Power frequency trip curren (Ii) | 3A |
mechanical endurance(time) | 1000 |
Maximum terminal connection | 25mm2 |
IP | IP20 |
Working environment temperature | -25℃~60℃ |
Working environment humidity (room temperature) | 20%~90%RH |
Installation rail | EN60715(35mm) |
Surge Special Circuit Breaker (SCB) basic info:
Surge special back-up protection device, referred to as SCB or SSD,
is a lightning protection device in recent years, more than 120
years later than the fuse. Its working principle is based on the
lightning current and power frequency current transmission speed of
different, through the internal circuit design, to achieve the
transient current and power frequency current to distinguish, and
through different paths to shunt it.
The fuse, circuit breaker work with SPD can not do:
1, SPD deterioration, distribution line abnormal overvoltage, Can
cause SPD to lead short circuit to the ground, fuse and circuit
breaker can not break fast at this time, SPD fire frequently
occurs.
2, when there is a lightning strike, because the fuse and circuit
breaker design in the early stage as distribution components used,
can not bear the instantaneous energy of lightning current,
resulting in device explosion and tripping, SPD failure at this
time.
3. When the lightning current passes through the circuit breaker,
the Up value (voltage protection level value) is very high, and the
SPD cannot play a protective role.
4, the fuse, circuit breaker short circuit analysis ability can not
be used in thetransformer into the line, short circuit accident can
not be cut off.
SCB series connection in front of SPD can do:
1.SCB can quickly cut off the access to prevent the lightning
protection device from catching fire when the lightning protection
device deteriorates and the distribution line has abnormal
overvoltage, so that the lightning protection device conducts short
circuit. Cut off current less than 3A;
2.When there is a lightning strike, the SCB connected in series in
the front end of the lightning protection device can ensure that
the 100KA lightning does not trip, not damage. To ensure the
continuous and effective function of the lightning protection
device;
3.The Up value (voltage protection level value) of SCB is very low
when it passes through the lightning current, which is equivalent
to the copper conductor of equal length;
4. Short-circuit breaking capacity exceeds that of MCCB up to
100KA;
SCB Application:
It is applicable to the places where SPD lightning protection
equipment has been installed, such as: industrial and civil
construction, electrical, communication, road traffic,
petrochemical and other industries of power equipment