Automatic Control Environmental Test Chambers , Temperature Shock Test Chamber

Brand Name:HAIDA
Certification:ISO 9001:2000; ISO 9001:2008; QS-9000; ISO 14001:2004; CE, , SMC, CMC, CPA, CE,CMA,IMC
Model Number:HD-E703
Minimum Order Quantity:1 Set
Delivery Time:20 days after order confirmed
Payment Terms:L/C,D/A,D/P,T/T,Western Union,MoneyGram,In cash, escrow
Contact Now

Add to Cart

Verified Supplier
Location: Dongguan Guangdong China
Address: Room 105, Building F4, District F, Tianan Digital City, Nancheng District, Dongguan City, Guangdong Province,China
Supplier`s last login times: within 48 hours
Product Details Company Profile
Product Details

Automatic Control Environmental Test Chambers , Temperature Shock Test Chambe


Product Usage:

Environment Temperature Shock Test Chamber have a automatic control system for the hot and cold temperature testing .

Touch screen high low temperature shock test chambers can be used in testing composite material and material structure’s result which under continuous environment with high temperature or low temperature shock in short time; it means this product can test the material’s chemical change or physics change by expansion and contraction within short time. It’s application to metal, plastic, rubber, electronic etc materials and can be used for product improvement’s reference.

Product Features:

1) Perfect outlook upgrades, easy operation

2) The color touch microcomputer temperature controller was made in Japan which can display Chinese / English Vertical structure with 3 chambers, high low temperature shock cycling can be automatic control, remain and change time can be adjustable, stainless steel inner material, several record methods, it has various safety precautions and device.

3) Perfect protect alarming function: when it has condition with short circuit, work chamber over-temperature, leakage; compressor with over-pressure, over-load, oil pressure, water-break, the screen will automatic display the fault cause and provide exclusion method, and when the input voltage is unstable, due to it has the stop device that the remove time of high-low temperature shock structure within 10s.

4) The recovery time for this product within 5min and meet MTL, IEC, JIS, GJB etc standard.

The Main Parameters:


ModelHD-E703-50K40HD-E703-50K55
Nominal content product(L)50
Interior dimension(mm)350×400×350(W×H×D)
Overall dimension(mm)1230×1500×1830(W×H×D)
Technical parametersTemperature range
High temperatureRT~170 ℃
Low temperature-75℃ ~RT
Test area-40℃ ~150℃-50℃ ~150℃
Temperature shock rangeHigh temperature60℃ ~150℃
Low temperature-10℃ ~-40℃-10℃ ~-50℃
Normal temperature areaRoom temperature
Temperature and humidity deviation±0.3℃,±2%R·H
Average difference in temperature and humidity±2℃,±3%R·H
Heating rate2℃/min
Cooling rate0.5~1.2℃/min
Storage timeRT→-75℃≤ 65min
Heat storage timeRT→170℃≤ 35min
Refrigeration systemCompressorImport of France taikang/Germany
Cooling wayWater cooling or air cooling
CondenserStainless steel brazed plate type heat exchanger
Heater/evaporatorNickel-chromium electric heater/finned evaporator
Microcomputer & display screenTT-5188T3-7HL Taitong controller
Circulation fanAxial flow fan
Safety measuresNo fuse switch, compressor overpressure, overheat, overcurrent protection, fuse, water flow protection, phase sequence protection, oil pressure protection, pressure relief protection, low pressure protection, pressure cylinder protection, temperature limit protection
MaterialChassis shellHigh quality cold rolled steel sheet is sprayed with static electricity
Inner wall of the caseSUS304# Stainless steel plate
Heat preservation materialPolyurethane rigid foam + high density fiberglass cotton
Standard configurationTest hole, floodlight, double vacuum bulletproof glass observation window
Power supplythree-phase,380V,50Hz

Functional Module:

  • The equipment is designed as an integral structure, directly in front and above is the test studio, in front and below is the preheating studio, in the back and above is the pre-cooling studio, in the back and below is the refrigerating unit mechanical room, the top of the equipment is installed with room temperature impact circulation duct and blower, the right side of the equipment is the electrical control box
  • Refrigeration system:

1.Using French taikang compressor, and the use of American dupont environmental refrigerant (R404a), using dual low temperature loop system design.

2.Temperature and humidity control adopts P.I.D + S.S.R system to coordinate with the channel control, with the function of automatic calculation.

3.Imported controller is adopted for temperature and humidity. The relative temperature and humidity performance is set and displayed accurately. The resolution reaches 0.1℃.

  • Control system: with imported LCD programmable temperature controller can do the program test, can have many groups of multi-section programming operation, fixed value and program optional, time arbitrary setting function.

China Automatic Control Environmental Test Chambers , Temperature Shock Test Chamber supplier

Automatic Control Environmental Test Chambers , Temperature Shock Test Chamber

Inquiry Cart 0