The principle of:
In short, a diesel generator drives a generator to run.
In THE cylinder, THE CLEAN AIR FILTERED BY THE AIR FILTER IS fully
mixed WITH the high-pressure atomized diesel jet from the fuel
injector. Under the extrusion of the piston, the volume shrinks and
the temperature rises rapidly, reaching the ignition point of
diesel. Diesel is ignited, the mixture of gas burning violently,
the volume of rapid expansion, push the piston down, called 'work'.
Each cylinder works in a certain order, and the thrust force acting
on the piston becomes the force driving the crankshaft rotation
through the connecting rod, thus driving the crankshaft rotation.
When the brushless synchronous alternator is installed coaxial with
the crankshaft of the diesel generator, the rotation of the diesel
generator can be used to drive the rotor of the generator. By using
the principle of "electromagnetic induction", the generator will
output the induced electromotive force, and the closed load loop
can generate current.
Here only the most basic working principle of the generator set is
described. A range of diesel generators and generator controls,
protection devices and loops are also required to achieve usable,
stable power output
Engine Data:
Manufacturer / Model: | DCEC Cummins 6CTA8.3-G2, 4-cycle |
Air Intake System: | Turbo, Water/Air Cooling |
Fuel System: | PB/W type fuel pump |
Cylinder Arrangement: | 6 in line |
Displacement: | 8.3L |
Bore and Stroke: | 114*135(mm) |
Compression Ratio: | 17:1 |
Rated RPM: | 1500rpm |
Max. Standby Power at Rated RPM: | 180KW/244HP |
Governor Type: | Electronic |
Exhaust System | |
Exhaust Gas Flow: | 34.7m3/min |
Exhaust Temperature: | 570℃ |
Max Back Pressure: | 10kPa |
Air Intake System | |
Max Intake Restriction: | 6kPa |
Burning Capacity: | 12.4m3/min |
Air Flow: | 238m3/min |
Fuel System | |
100%( Prime Power) Load: | 215 g/Kw.h |
75%(Prime Power) Load: | 211 g/Kw.h |
50%(Prime Power) Load:: | 216 g/Kw.h |
100%( Prime Power) Load: | 39.7L /h |
Oil System | |
Total Oil Capacity: | 23.8L |
Oil Consumption: | ≤4g/kwh |
Engine Oil Tank Capacity: | 18.9L |
Oil Pressure at Rated RPM: | 276-414kPa |
Cooling System | |
Total Coolant Capacity: | 34L |
Thermostat: | 82-95℃ |
Max Water Temperature: | 104℃ |
Alternator SpecifiCAT-parts-partsion:
GENERAL DATA
Compliance with GB755, BS5000, VDE0530, NEMAMG1-22, IED34-1, CSA22.2 and AS1359 standards.
Alternator Data:
Alternator Data | |
Number of Phase: | 3 |
Connecting Type: | 3 Phase and 4 Wires, “Y” type connecting |
Number of Bearing: | 1 |
Power Factor: | 0.8 |
Protection Grade: | IP23 |
Altitude: | ≤1000m |
Exciter Type: | Brushless, self-exciting |
Insulation Class, Temperature Rise: | H/H |
Telephone Influence Factor (TIF): | <50 |
THF: | <2% |
Voltage Regulation, Steady State: | ≤±1% |
Alternator Capacity: | 182KVA |
Alternator Efficiencies: | 92.4% |
Air Cooling Flow: | 0.514m3/s |