Automatic Voltage Regulation Small Gasoline Generator 5kva 8kva 10kva

Brand Name:GSKA
Model Number:SF5600i/SF3600i
Minimum Order Quantity:1-5 pieces
Delivery Time:one weeks on receipt of official sales contract
Payment Terms:L/C,D/P,D/A, Alipay, West Union, TT. Cash,Paypal
CertifiCAT-partsion:CE,GS,EPA,CARB,CSA
Contact Now

Add to Cart

Verified Supplier
Location: Dongguan Guangdong China
Address: No. 2, Shajiao Sijia Gate, Humen Town, Dongguan City, Guangdong Province, China
Supplier`s last login times: within 48 hours
Product Details Company Profile
Product Details

Automatic Voltage Regulation Small Gasoline Generator 5kva 8kva 10kva


Common faults:


Can't power:


(1) Check and correct wiring errors according to the circuit diagram.


(2) The excitation windings of the main generator or exciter are connected incorrectly, resulting in incorrect polarity. It is often caused by wiring error after replacing the excitation winding. It should be checked and corrected.


(3) Rotary silicon rectifier element breakdown short circuit, positive and negative conduction. Use a multimeter to check the positive and negative resistance of the rectifier element and replace the damaged element.


(4) The excitation winding of the main generator is broken. Use a multimeter to check and measure the excitation windings of the main generator. The resistance is infinite and the excitation line should be connected.


(5) The winding of the main generator or exciter has a serious short circuit. The armature winding has a short circuit, which is generally obvious overheating. The short circuit of the excitation winding can be determined by the resistance value of its tributaries. Replace the damaged winding.


The principle of:


A working cycle includes four piston strokes (the so-called piston stroke refers to the distance between the piston from top dead center to bottom dead center) : intake stroke, compression stroke, expansion stroke (work stroke) and exhaust stroke.


Intake stroke:


During this process, the engine's intake valve opens and the exhaust valve closes. As the piston moves from top dead center to dead center, the cylinder volume above the piston increases, so that the pressure in the cylinder drops below the atmospheric pressure, that is, the vacuum suction is caused in the cylinder, so that the air is sucked into the cylinder through the intake pipe and intake valve, and the oil nozzle spray atomized gasoline and air are fully mixed. At the end of the intake, the gas pressure in the cylinder is about 0.075-0.09MPa. The temperature of the combustible mixture in the cylinder has risen to 370-400K.


Compression stroke:


In order to make the combustible mixture inhaled into the cylinder can burn quickly, so as to produce greater pressure, so that the engine emits higher power, must be compressed before combustion, so that its volume is reduced, the density is increased, the temperature is increased, that is, there is a compression process. In this process, the intake and exhaust valves are all closed, and the crankshaft pushes the piston from BDC to DC to move one stroke, that is, the compression stroke. At this time, the mixture pressure will increase to 0.6-1.2MPa, and the temperature can reach 600-700K.


specifiCAT-parts-partsion parameter:


ModelSF3600iSF5600i
TypeForced Air-Cooled,1-Cylinder, 4-Stroke,OHV
DisplacementHONDA 270HONDA 390
Rated Power Output5.1 KW/3600 RPM6.6 KW/3600 RPM
Max.power Output6.2 KW/4200 RPM8.2 KW/3600 RPM
Bore* Stroke(mm)77*58 mm88*64 mm
Lgnition SystemT.D.IT.D.I
Starting SystemRecoil Starting/Electric/RemoteRecoil Starting/Electric/Remote
Recommend Power Using
Fuel Tank Capacity13L13L
Fuel Consumption450g/kw.h299g/kw.h
Continous Operating Hour78.5
Noise( 7 m away)59 dba68 dba
Rated Output Frequency50 Hz/60 Hz50 Hz/ 60 Hz
Rated Output Voltage110V/120V/230V/240V110V/120V/230V/240V
D.C. Output12V 8.3A12V 8.3A
A.C. Output110V/120V/230V/240V110V/120V/230V/240V
How Many output35
Rated Power Output(KVA)35
Max.Power Output(KVA)3.35.5
Total Length600 mm700 mm
Total Width450 mm480 mm
Total Height500 mm600 mm
Net Weight55 kg75 kg
Packing Size(mm)650*510*565 mm750*570*795 mm
Large-capacity Air CleanerNN
Fuel IndiCAT-parts-partsorYY
VoltmeterNN
Auto Voltage AdjustorYY
Oil Alert SystemYY
Curcuit Breaker without FuseYY
Circuit ProtectorYY
Parallel Connection BoxNN
Digital Display Control PanelNN
20" Container( UNIT)MOQ 150MOQ 80
40" Container( UNIT)320170
40' HQ(UNIT)400180
CertifiCAT-parts-partsesCE,GS,EPA,CARB,CSACE,GS,EPA,CARB,CSA


China Automatic Voltage Regulation Small Gasoline Generator 5kva 8kva 10kva supplier