Add to Cart
2.5Hp/3600rpm Portable Mini Silent Mechanical Engine 1KW 110V 220V
Precautions:
1) Theory guides practice. It is necessary to master the basic
principle and structure of small gasoline engines in order to
analyze and deal with faults, especially for different types of oil
engines.
2) When a fault occurs, it is necessary to conduct a comprehensive
and scientific analysis and judgment according to the site to
ensure the accurate treatment of the fault, rather than relying on
imagination or the so-called experience in the past to deal with
the problem. Gasoline engines often have oil circuit, circuit and
other parts of the fault at the same time, resulting in more
complex fault phenomenon, sometimes different fault points will
appear similar phenomenon, causing certain difficulties in
troubleshooting. The scope and loCAT-parts-partsion of the fault
can be determined by analyzing and comparing the possible causes of
the fault by combining the fault phenomena observed on the spot.
Then from simple to complex, from the surface to the inside, first
analyze the circuit after the analysis of the oil circuit, and then
adjust the ignition time, check the order of gas distribution
timing, the fault compression to a certain point;
3) Develop good habits, do the necessary check work before starting
the machine, and make regular inspection in the operation of the
machine, as far as possible to avoid sudden failures;
4) At ordinary times, strictly carry out technical maintenance of
the oil machine at all levels to ensure that the oil machine is in
good working condition and avoid the occurrence of sudden failures
and major accidents
Sound suppression treatment:
Gasoline generator noise is a wide band spectrum characteristics,
and the muffler equipment can resist high airflow speed and high
temperature, high pressure, and not afraid of water and humidity,
when the temperature rises, the performance of the muffler is
little changed, according to this situation, the treatment of the
micro perforated plate compound muffler. The microperforated plate
muffler with the diameter of 0.5 ~ 1mm and the perforation rate of
1% ~ 3% is machined from 0.5 ~ 1mm thin steel plate. It has a good
absorption effect on medium and high frequency noise. For
multilayer cases, the thickness of the cavity depends on the
absorption frequency band. The thickness of the cavity is 150-220mm
when the low frequency is 125-250Hz, and the thickness of the
cavity is 80-120mm when the medium frequency is 500-1000Hz. When
the high frequency is 2000-4000Hz, the cavity is 30-50mm. In order
to prevent the propagation of sound waves along the long direction
of the tube in the cavity of the micro-perforated plate, a
transverse baffle is added for every 0.5m length of the muffler
that needs a higher noise attenuation. The cross section of the
double-layer micro-perforated sheet tube muffler is circular.
Product Description:
DIGITAL INVERTER GENERATOR 3.3HP/2KW | |
Model Number | 8896219 |
Number of phases | 1 ph |
Maximum power | 2kw |
Rated power | 1.85kw |
Voltage/frequency | 230v/50hz |
Power factor | 1 |
Engine | |
Max.engine power | 2.5kw(3.3hp/5500/min) |
Displacement | 80cc |
Starting | recoil |
Consumption | approx. 0.9 1/kwh |
Tank volume | 4.5 l |
Generator | |
Type of generator | multipole,digital control,inverter. |
AC rated current | 8.0A/230V |
DC rated current | 8.3A/12V |
Weight | 21.6kg |
Dimension | 42x52x29cm |