500w Pure Sine Wave UPS Low Frequency Solar Inverter Single Phase Automatic Door
Passive backup UPS power supply:
The inverter is connected in parallel between the mains and the
load and is simply used as a backup power source. This UPS power
supply, when the mains is normal, the load is completely and
directly local power supply, the inverter does not do any power
conversion, the battery is powered by an independent charger; When
the mains is not normal, the load is completely supplied by the
inverter.
Passive backup UPS has the advantages of simple structure and
cheapest price. It is used for some non-essential load use, such as
home computers. However, when the mains power is off, the relay
will switch the inverter to the load. The switching time is
relatively long, which generally takes a few milliseconds to
interrupt, so the passive backup UPS power supply should not be
used for slightly important computer equipment.
Online interactive UPS power supply:
Refers to the inverter connected in parallel between the mains and
the load, plays the role of backup power supply, while the inverter
as a charger to charge the battery. Through the reversible
operation of the inverter, it interacts with the mains, so it is
called interactive. This UPS power supply, when the mains is
normal, the load is powered by the improved mains, and the inverter
is used as the charger to charge the battery. At this time, the
inverter plays the role of AC/DC converter; And when the mains
failure, the load is completely powered by the inverter, at this
time, the inverter plays the role of DC/AC converter.
The on-line interactive UPS has the advantages of simple structure,
convenient implementation, easy parallel connection, easy
maintenance and repair, high efficiency, low operating cost, high
reliability of the whole machine, and the performance can meet some
load requirements, especially suitable for some computer equipment
in the network using distributed power supply system. The
disadvantage of this kind of power supply is low voltage
performance, especially low dynamic response speed, second
anti-interference ability is not strong, the circuit will produce
harmonic interference and modulation interference.
Model | GSKA-500 | GSKA-800 | GSKA-1000 | GSKA-1500 | GSKA-2000 | GSKA-2500 | GSKA-3000 | GSKA-5000 | |
Rated Capacity | 500VA | 800VA | 1000VA | 1500VA | 2000VA | 2500VA | 3000VA | 5000VA | |
Rated Power | 300W | 500W | 700W | 1050W | 1400W | 1800W | 2100W | 3500W | |
Transformer | Toroidal transformer | ||||||||
Interface | LED graphic | ||||||||
Display status | working&loading&battery | ||||||||
Working mode | PV(Photovoltaic priority)/AC(AC priority) optional | ||||||||
Input | Voltage | 140-275Vac | |||||||
Frequency | 45-65Hz | ||||||||
Output | Voltage | 220Vac±3% for inveter; 195v-240V for avr | |||||||
Frequency | 50/60Hz ± 0.3Hz, subject to the main | ||||||||
Wave Form | Pure sine wave | ||||||||
Wave Distortion | ≤3% | ||||||||
Protection | overload/high temperature/output high voltage /output low voltage/ battery low voltage shortcircuit/over-charge/over-discharge/reversed polarity(optional) | ||||||||
Transfer Time | ≤4ms | ||||||||
Battery Voltage | 12VDC | 24VDC | 48VDC | ||||||
Charge Voltage | 13.6V±0.3V | 27.2V±0.6V | 54.5V±1V | ||||||
Low Battery Voltage Limit | 10.9V±0.3V | 21.8V±0.5V | 42V±1V | ||||||
Protections Battery Low Voltage Protection Point | 10.2V±0.3V | 20.5V+0.5V | 41V±1V | ||||||
Charge Current | Max.10A/15A/20A optional | ||||||||
Environmental | Operating Temperature | 0~40℃ | |||||||
Relative Humidity | 10%~90%RH,non-condensing | ||||||||
Storage Temperature | -15-45℃ | ||||||||
Packing | Machine Size(mm) | 280x144x213 | 385x190x320 | ||||||
Qty/Ctn | 4 | 4 | 2 | 2 | 1 | 1 | 1 | 1 | |
Carton Size(mm) | 785x305x240 | 415x410x245 | 410x290x320 | ||||||
CartonG.W.(kg) | 22 | 26 | 17.2 | 19.1 | 410x290x321 |