Parking Lot Management System Backup Battery Servo DC 24V Parking Barrier Gate

Brand Name:WONSUN
Certification:CE
Model Number:DZ-V01 for Parking Lot Management System
Minimum Order Quantity:1PC
Delivery Time:3-7 working days after received your payment
Payment Terms:T/T,Western Union,Money Gram,Alibaba Trade Assurance,Paypal etc.,
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen Guangdong China
Address: 1st Floor, Zhigu, No. 2-10, South jinlong Avenue, Shahu Community, Biling Street, Pingshan District, Shenzhen, China
Supplier`s last login times: within 25 hours
Product Details Company Profile
Product Details

Servo DC 24V Palang Parkir Barrier Gate Backup Battery for Parking Lot Management System

Functions and Features Parking Lot Management System

1. Open and close speed adjustable

2. Arm direction Left and Right can change easily

3. When power off, manual open and close arm, and lock itself.

4. Wireless remote

5. Photocell I0 port output

6. Loop detector anti-collision I0 output

7. Open and close control input

8. 12V traffic light output

9. Traffic light signal output

10. Open and close limit signal output

11.Counting (fleet) input RS485 communication input

12. 24V battery input port

13. Delay close arm function(1-300 sec. Adjustable)

Electrical installation and wiring diagram

1. The internal wiring of the machine has been completed when it leaves the factory, please do not

change it, just connect the 220V power supply and the protective ground wire to work.

2. Traffic light interface: 2A12V voltage traffic light use.

3. Infrared anti-smashing interface: external infrared anti-radiation device, just connect the switch

signal of the anti-radiation output.

4. Ground sense interface: support external ground sense. When using an external ground sensor,

you only need to connect the switch signal output by the ground sensor.

5. Parking system interface wire control interface: connect the switch signal of the system to this

interface to control the barrier.

6. Starting limit and landing limit signal output: output COM/NO/NC switch signals to the system to

inform the current state of the barrier.

7. RS485 communication interface: PC software can be used to manage more than 15 barriers.


Spring installation,disassemble and replacement Parking Lot Management System

Disassemble step as below: put arm on vertical position


1. Unscrew the M8*140MM screw with a hexagonal spanner

2. Calibrate gate arm position

To calibrate the position of the barrier arm (for example, after applying excessive force), follow the steps below:

1. Open the door of the barrier box and remove the cover.

2. Loosen the two fastening screws of DZ-1 on the pendulum shaft with an M12 Allen key, so that the barrier

arm can be repositioned by hand.

3. Calibrate the position of the barrier arm (horizontal position, as shown in Figure 1).

4. Retighten the two fastening screws with a hex wrench

Servo barrier function setting parameter table

MENU NO.Parameter scaleParameter nameDefaultUnitRemark
H00-0010-100Maximum speed of open arm25Percentage; the default maximum speed of the motor is 2000RPM
H00-0110-100Maximum speed of close arm25Percentage; the default maximum speed of the motor is 2000RPM
H00-025-40

Minimum speed of open arm

5Percentage; the default maximum speed of the motor is 2000RPM
H00-035-40Minimum speed of close arm5Percentage; the default maximum speed of the motor is 2000RPM
H00-0450-420

Open arm deceleration angle

20.0The smaller the parameter, the faster the speed; 50 means 5.0 degrees

Error code:

1:EFF-01Check the motor or wiring.Generally, the motor or the motor wire is not connected properly.
2. EFF-02The voltage is lower than 22.0Vthe switching power supply or the battery voltage is not enough
3. EFF-03The load is too heavy or the drive board is damaged, and the motor wiring is wrong.Check whether the motor wires are in good contact, and replace the drive. Or load
4. EFF-04If the limit is not reached for 5 consecutive timesReset the limit point, or eliminate the problem of the limit device
5. EFF-05Occurs during self-inspection, or the motor is stuck or the load is too heavy

FAQ


1-Can you install using loop detector or pressure sensor on it?

Yes,the stanadard advertising barrier gate have loop detector and pressure sensor.


2-How about the guarantee and after sale service?

We have 1 year quality guarantee, We own well tranied and passional sales & aftersale services who can speak fluent English language.


3-How long is the leading time?

For standard item

10-50 sets:5 working days
50-100 sets:7-10 working days
200-500 sets:10-15 working days
For special item, or need custom design package or logo, need 3-10 working days longer.


4-How about the payment terms?

TT,western union,our company already joined the trade assurance,it will highly protect your order security.

Palang Parkir Barrier Gate Backup Battery for Parking Lot Management System

Palang Parkir Barrier Gate Backup Battery for Parking Lot Management System

Palang Parkir Barrier Gate Backup Battery for Parking Lot Management System

China Parking Lot Management System Backup Battery Servo DC 24V Parking Barrier Gate supplier

Parking Lot Management System Backup Battery Servo DC 24V Parking Barrier Gate

Inquiry Cart 0