6KA Breaking Capacity Miniature Circuit Breaker 6A 10A 16A 20A 25A 32A 40A

Brand Name:KRIPAL
Certification:CE
Model Number:UKB71-40 B curve
Minimum Order Quantity:1000 pcs
Delivery Time:20 days and depends on ordering quantity
Payment Terms:T/T, L/C
Contact Now

Add to Cart

Active Member
Address: Daqiao Industrial Zone, Baixiang Town,Yueqing 325603,Zhejiang, China
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

6KA Breaking Capacity Miniature Circuit Breaker 6A 10A 16A 20A 25A 32A 40A



Electrical Specification


Conform to standard of electricalEN60898 (IEC898) GB10963
Rated Voltage (Ue)230V;50/60Hz
Rated breaking capacity6KA
Rated current6-40A
Trip characterB type characteristics curve
Max fuse that can be connected toMax 100A gL (>6KA)
Selection grade3
Work environment temperature-5 to +40℃
Case protection gradeIP40 (after installation)
Life≥8000 times (on-off)

Machine Parameter


The length of exposed plane45mm
Enclosure height80mm
Enclosure width17.5mm (1P+N)
Moutily mannerThe standard IEC 35mm rail
Terminal mannerTerminal connection of exaltation
Terminal block capacity1-16mm2

Accessories


Auxiliary contact, Contact with alam indication, Generatrix line


Outline and Installation Dimensions



UKB71 1P+N B Curve 6KA breaking capacity Mini Circuit Breaker 6,10,16,20,25,32,40A


Main Feature


1.High breaking capacity up to 6KA

2.Small dimension and one modular quantity with

3.Wise current scope up to 40KA

4.Performace of the functions of overload and short-circuit protection.

5.Suitable for protection to the civil lighting and socket circuit. The neutral line break for safer and more reliable.


UKB71 1P+N B Curve 6KA breaking capacity Mini Circuit Breaker 6,10,16,20,25,32,40A


Order No.


Order Type
Current (A)B Curve
6AUKB71-40/1N/B6
10AUKB71-40/1N/B10
16AUKB71-40/1N/B16
20AUKB71-40/1N/B20
25AUKB71-40/1N/B25
32AUKB71-40/1N/B32
40AUKB71-40/1N/B40

Circuit diagram



UKB71 1P+N B Curve 6KA breaking capacity Mini Circuit Breaker 6,10,16,20,25,32,40A


Tips:


1. MCB is for non-professional operation by those untrained, and no maintenance is required


2. Satisfying conditions and applications as mentioned above,MCB with “ON-OFF” indicating device is considered suitable for isolation function.


3. Particular devices such as surge protective devices,surge arrester etc are recommended to install at upstream line to MCB as precaution against potential surge voltage and current occurring at its power input side.


4. Appropriate tripping curve being chosen and properly installed, MCB trips and switches off its protected circuit in case of fault, and thus provides protection against electric shock.

China 6KA Breaking Capacity Miniature Circuit Breaker 6A 10A 16A 20A 25A 32A 40A supplier

6KA Breaking Capacity Miniature Circuit Breaker 6A 10A 16A 20A 25A 32A 40A

Inquiry Cart 0