UL1054,UL943,IEC60669 Clause 18.3
Application
The overLoad test is achieved by connecting the number of 30
halogen lamps rated at 200W in parallel .
Lamps of any power can be used to reach the rated load.
Technical parameters:
Input power | AC 220V, 20A, 50/60Hz (It depends on customer's national requirements) |
the output voltage | AC 0 ~ 250V continuously adjustable,4 display instrument display, accuracy 0.5% |
Output current | 0~24 A(can be customed) |
Test current | This is achieved by connecting the number of halogen lamps rated at 200W in parallel. (Number of filament lamps: 30, switch rated current 16A); |
Number of filament lamps | 30 (can be customed) |
Touch screen display | Test voltage, test current, number of tests, bulb failure location, warning light information. |
Counter | 1 ~ 999999 times can be preset |
The number of output channels | 1 |
Overtime protection | with the test current continuous power circuit protection function for 5 seconds. |
surge current coefficient | Meet the requirements of UL1054 5.7.9, about 10-18 times. |
The control plane size | About 1200 × 800 × 1700 (mm) |