Add to Cart
IEC 60898-1 Electrical Appliance Tester Circuit-breaker Tripping Characteristic Test
Standard: IEC 60898-1 clauses (8.6, 9.10) tests of tests of time-current characteristics of circuit-breakers.
Application: This device is intended to test the time-current characteristics of the circuit-breakers.
Test sample: Circuit-breakers for overcurrent protection for household and similar installation.
Feature: This equipment has special monitoring and control software, which can be fully automatic controlled by using pc computer.
Main Parameters:
1. Control system: touch screen and 32-bit embedded high-speed industrial-grade single-chip microcomputer
2. Device capacity: 8 channels, each channel 2kVA, a total of 16KVA;
3. Input cable diameter: ≥10mm
4. According to standards, when testing the multiple current continuously for 2 to 8 hours, the maximum multiple does not exceed 3In, and the conductor does not change color.
5. 100-type output current range 1A~300A, sine waveform distortion degree<5% (related to input power);
6. 100-type current transformer ratio is 300/5A, accuracy of 0.2;
7. Input gas source: 0.6 ~ 0.8Mpa, Q6 pipe diameter;
8. Timing range: 1s ~ 9H59M59s, resolution of 1s;
9. Insulation resistance of equipment: ≥5MΩ;
10. Systematic error: ≤±2%;
11. Test current: ≤±1%
12. Fluctuation range: ≤±1%;
13. Test fixture: 8 sets;
14. Screen display: current, time;
15. Height of the worktable is 850mm, process aluminum Alloy structure, fixture dual activity type, worktable detachable structure;
16. equipment for the process of aluminum alloy structure, the external dimensions of 1800 * 1100 * 1700, aluminum alloy for 40 × 80, the appearance of the color is white;
17. Equipment power supply voltage: 220V ± 5%, 50Hz;
18. Communication Interface: RS232;
19. Host computer: special monitoring and control software, computer hardware using Dell brand business computer
Control system | touch screen and 32-bit embedded high-speed industrial-grade single-chip microcomputer |
Device capacity | 8 channels, each channel 2kVA, a total of 16KVA |
Input cable diameter | ≥10mm |
Input gas source | 0.6 ~ 0.8Mpa, Q6 pipe diameter |
Timing range | 1s ~ 9H59M59s, resolution of 1s |
Insulation resistance of equipment | ≥5MΩ |
Systematic error | ≤±2% |
Test current | ≤±1% |
Fluctuation range | ≤±1% |
Test fixture | 8 sets |
Screen display | current, time |
Height of the worktable | 850mm |
dimension | 1800 * 1100 * 1700mm |
Equipment power supply voltage | 220V ± 5%, 50Hz |
Communication Interface | RS232 |