Add to Cart
IEC 60669-1 Load Bank, Plug Socket Tester, 220V 50Hz Single station
Standard: IEC 60669-1, IEC 60884-1 2013 clause 20 and 21, IEC 60950-1, IEC 60598-1, IEC61058-1 and so on
Product Introduction: The load boxes are designed and manufactured according to IEC60884, IEC61058, IEC606691 standards and etc. It is applicable for household and similar fixed electrical installations switches and plug sockets breaking capacity and normal operation test, the rated voltage of the switch is not greater than 280V and the rated current less than 16A. The purpose is assessing whether the switch is able to withstand the normal use of mechanical damage and electrical fatigue damage, and whether the contacts has adhesion phenomenon, long-term closed or disconnected phenomena, to examine whether the test samples excessive worn and have other harmful consequences.
Plug Socket Tester
The frame and side panels of the load box is light gray. Front top is the operator control panel, the panels are made of high quality aluminum plate, etching sandblasting colored craft, attractive and durable. There are power switch/current/voltage and power/power factor displaying instruments, load power switches, status indicators, start and stop buttons, capacitance switches, load switches and alarms etc. Below corresponds to the output voltage regulation knobs, output current regulation knobs and power factor regulation knobs. The load box has resistive, inductive and capacitive (fluorescent type) load three in one feature, they are switchable. The interior of the load box is cooled by strong wind convection cooling. At the back of the load box there are wire connecting terminals, the load box outputs current voltage and power during the detection by connecting the wire with the test samples on the endurance test machine. Plug Socket Tester
Technical Parameters
No | Item | Parameter |
1 | Power Supply | single-phase 220V, 50Hz. |
2 | Stations | single station(Customizable) |
3 | Digital voltage meter | Range 0 ~ 300V accuracy ± 05% ± 2d |
4 | Digital ampere meter | Range 0 ~ 30A accuracy ± 05% ± 2d |
5 | Digital power meter | Range 0~10KW, accuracy±05% |
6 | Digital power factor meter | 0.3~0.98, accuracy: ±0.5% |
7 | Load method | Resistive, Inductive and Capacitive load three in one, Convertible |
8 | Capacity load | 70uf, 140uf, 7.3uf can be chosen |
9 | Load output | Each power, Interval power can be chosen |
10 | Count/Preset | 0~999999 times, can be preset Plug Socket Tester |
11 | Load capacity | 10KVA |
12 | Max. of the output current | 30A,when it exceeds 32A, it stopped automatically |
13 | Max. of the output voltage | 300V, when it exceeds 305V, it stopped automatically |
14 | Working environment | 80~106kpa, 5~40℃, (20~90)%RH |
15 | Using place | No violent shaking, without electromagnetic interference and dust, no explosive or corrosive gas. |
16 | Dimensions and weight | L*W*H= 760*700*1700mm, 276kg |
Picture for reference: