Purpose of Flammability Testing Equipment:
The test apparatus for testing the resistance to vertical flame
propagation for a single vertical electrical insulated conductor or
cable, or optical fibre cable, under fire conditions.
Standard of Flammability Testing Equipment:
IEC 60332-1-1 Tests on electric and optical fibre cables under fire conditions – Part 1-1: Test for vertical flame propagation for a single insulated wire or cable – Apparatus;
IEC 60332-1-2 Tests on electric and optical fibre cables under fire conditions – Part 1-2: Test for vertical flame propagation for a single insulated wire or cable – Procedure for 1 kW pre-mixed flame;
IEC 60332-1-3 Tests on electric and optical fibre cables under fire conditions – Part 1-3: Test for vertical flame propagation for a single insulated wire or cable – Procedure for determination of flaming droplets/particles;
Feature:
This series of products adopt integral type inlet ignition system.
The combustion time delays 0.1S thus to make sure the sufficient
time of gas burning. They are with matte black background,
multi-functional flame measure gauge, stainless steel of box full,
large observation window, imported digital indicator of high
precision, nice appearance. And they gather a number of advantages
of similar products home and abroad.
Parameters of Flammability Testing Equipment:
Working voltage | 220V/50-60Hz |
Control operation mode | Electrical control, button operation |
Blast burner standard | IEC60695-11-2 Annex A, Burner opening:Φ7±0.05mm,made of brass |
Gas flow and gas category | Mixture gas: 650±30mL/min propane;10±0.5L/min air,Dual flow meter adjustment |
Burning time | 9999X0.1S |
Burning angle | Tilt 45°±2°, Adjustable |
Test flame calibration | Temperature measuring copper head: 500W: Ф9mm±0.01mm, weight before drilling:10 ± 0 .05g |
Thermocouple: The American original Omega φ0.5 armour nickel-chromium/nickel aluminum wire K-Thermocouple, temperature resistance 1100° | |
Distance between the bunsen burner port to temperature measuring copper block:95 mm | |
Flame height: Inner flame:55±5mm, outer flame:180±10mm | |
Temperature rise time from 100±5°C to 700°±3°C 45±5s | |
Combustion chamber | WDH=300×450×1200±25mm |
Gas | >95% propane or coal gas |
Test sample | Length: 600±25mm, distance from the bottom:50mm |
Fixed horizontal support of the sample | 2, distance:550mm |
Dimension | WDH=700×450×1350mm, weight about 120kg |