Digital transmitter RS232 can be directly connected to the computer, RS485 can choose quality assurance

Model Number:display instrument for torque ,tension ,pull and weighting sensors
Minimum Order Quantity:Pls inquiry us !
Delivery Time:2-5 days
Payment Terms:T/T , Paypal, Western Union. Escrow etc.
Place of Origin:China
Price:USD $0.001-USD$1000.00
Contact Now

Add to Cart

Active Member
Location: Guangzhou Guangdong China
Address: Long Jin Road No. 4, Room 540, Long Jin Street , Liwan District , Guangzhou City, Guangdong, Province,
Supplier`s last login times: within 29 hours
Product Details Company Profile
Product Details

Sensor matching digital transmitter, RS232, RS485 output


Characteristic:


Stable and reliable performance measurement accuracy and intuitive, compact size, the use of flexible,Universal transmitter, suitable for all kinds of industrial equipment with PC monitoring software, equipped with complete detailed communication protocol, zero calibration, display calibration function.


Digital sensor communication protocol


1, protocol type: RTU MODBUS


Please refer to the specific RTU MODBUS protocol


MODSCAN software can be used to test


2, communication mode: RTU - RS485 MODBUS half duplex, master-slave mode


3,Serial data format: the use of 11 bit data format:

  • 1 bit start bit + 8 bit data bit + 1 bit parity check (EVEN) + 1 bit stop bit (MODBUS default mode)
  • Baud rate: 19200 baud

Message frame format of communication between sensor and host computer:


The message frame format of the sensor and the host computer is shown in table 1-3

(in which the current address range of the sensor: 0-99; sensor to receive and send data to a floating point conversion of four bytes, the company provides the host computer calibration procedures


Table 1

message frame format for MODBUS communication


Sensor address (one byte)Function code (one byte)Data (4 bytes)CRC check (2 bytes)

Table 2

data frame format for sensor transmission


Sensor current address(function code) 01HSensor data (4 bytes)CRCL+CRCH (2 bytes)

Table 3

frame information for sensor data


Function descriptionMessage frame format for sensor reception
Address field (sensor)function codeData domainCRC Check field
Zero calibrationCurrent address02H0000HCRCL+CRCH
Full range calibrationCurrent address03HFFFFHCRCL+CRCH
Sensor address modificationCurrent address04H0000H-00F7HCRCL+CRCH
Output for mV signalCurrent address05H0000HCRCL+CRCH
Output voltage signalCurrent address06HFFFFHCRCL+CRCH

  • Communication protocol in addition to the standard MODBUS protocol, but also according to the needs of customers to develop customized communication format.Sensor accuracy:100000/mV