Metal Oxide 54KV 5KA Class 2 Surge Polymer Housing Lightning Arrester for High Voltage Circuit


Application:


The zinc oxide arrester is mainly used to protect distribution transformer,cable

connector and electrical equipment from being damaged by lightning impulse

voltage and operating over-voltage.


Technical Specification:


1. The composite-sheath metal-oxide arrester applied in AC system.

1.1 Typical product parameters of composite-sheath metal-oxide arrester used under low-voltage.

( standard: IEC60099-4, GB11032-2000, JB/T8952-1999)


TypeYH5W5-54/136
Rated voltage---------kV54
MCOV ----------------kV43.2
Nominal Current-------kA5
Residual voltage of steep impulse----at 5kA(kV)148
8/20µS Residual voltage of lightning impulse current kV(Peak value)-----at 5kA(kV)136
Residual voltage of switching impulse current kV (peak value)----at 1kA (kV)/
1mA D.C reference voltage (kV)77
Line discharge level1
2mS long duration impulse current A400
4/10µS High current impulse kA100
Lightning impulse withstand kV250
Power frequency voltage withstand(dry/wet)kV140
0.1S TOV--------------kV64.8
1S TOV----------------kV62.1
10S TOV---------------kV59.4
1200S TOV-------------kV54
Creepage distance ----mm2070
Material employed in series non-linear resistorZinc Oxide

Ambient condition:


1. Ambient temperature: -40 °c ~40 °c;

2. Sun-rays radiation: the influences of max sun-rays radiation (note: 1.1kW/M2) have been taken into consideration through quality pre-heated method in type test. If existing any other heat sources around arrester, parties shall negotiate to decide whether to use or not;

3. Altitude: not over 1000m;

4. Power supply frequency: 48Hz~62Hz;

5. The P.F. voltage which bring pressure to bear between arrester terminals shall not exceed continuous operation voltage of arrester;

6. Earthquake intensity: not over 7 degree;

7. Wind speed: not over 35m/s.