Air Working Medium ASCO Submerged Type Pneumatic Pulse Valve QK25
with Port Size 1 Inch
About the classical ASCO submerged type Pulse Valve,the pulse valve input end (IN) is connected to the metal tube of the
gas storage cylinder, and the output end thereof is connected with
the dust blowing box blowing pipe, and the connecting thread is
filled with the tetrafluoroethylene raw material tape to be tightly
sealed.The Y-type pulse valve is a submerged valve (also known as an
embedded valve) that is mounted directly on the air bag for better
flow characteristics.
The pressure loss has been reduced, which is suitable for
workplaces with low air supply pressure.This type Pulse Valve are instock,If you are interesting,pls
contact us without any hesiratioln.
Model No. | QK25 |
Working Pressure | 0.3-0.8mpa’ |
Environment Temperature | -5~55℃ |
Relative Humidity | 〈85% |
Working Medium | Clean Air |
Voltage | AC110 AC220 DC24V |
Diaphragm Usage | Injection more than 1 million |
Other Specifications Can be Available
Detailed Datas as Follwos for Reference
Whole Set of Bag Dust Filter System Supply
The Usage of Pneumatic Pulse Valve :
The electromagnetic pulse valve (also known as the diaphragm valve)
is the compressed air "switch" of the pulse bag type dust collector
cleaning system. Controlled by the output signal of the pulse
controller, the filter bag is sprayed and cleaned row by row
(room), so that the resistance of the dust collector is kept within
the set range to ensure the dust collector Processing capacity and
dust collection efficiency.
The Z-type pulse valve is a right-angle valve with an angle of 90°
between the inlet and outlet. It is suitable for the installation
link between the air bag and the blow pipe. The air flow is
unobstructed and can provide the required cleaning gas pulse.
The Y-type pulse valve is a submerged valve (also known as an
embedded valve) that is mounted directly on the air bag for better
flow characteristics. The pressure loss has been reduced, which is
suitable for workplaces with low air supply pressure.
Preventive Maintenance of Solenoid Valve:
Keep the medium flowing through the pulse valve as smoothly as
possible to prevent dust and foreign matter from entering In use,
the valve should be run at least once a month to ensure normal
opening and closing;
Depending on the medium and operating conditions, it is recommended
to periodically check the internal parts of the valve for damage,
or excessive wear, thoroughly clean all parts (all valves should be
cleaned regularly, the cleaning interval varies according to the
medium and operating conditions, in general, If the voltage applied
to the coil is correct, then running hysteresis, noise, or
excessive leakage indicates that cleaning is required. In extreme
cases, valve operation may occur, or the valve may not open and
close. When cleaning the valve, it should be cleaned at the same
time. Filter or filter)
If you want to know more,pls contact us at once