

Add to Cart
Nass Type 0545 20W Solenoid Valve Coil 24V DC For Air Compressor Auto Drain Valve
The electronic drain valve is mainly composed of a solenoid valve
with 0545/0543 solenoid coil, a timer and a junction box. The
automatic drain valve is set for a period of time to perform a
drain operation on a regular basis.
1. The hot, humid and moisture-laden compressed air from the air
compressor is first pre-cooled by air to the air heat exchanger;
then the pre-cooled air is passed through the refrigerant in the
air-to-refrigerant heat exchanger. The circulation loop is further
cooled to exchange heat with the cold air that has been cooled from
the evaporator to the pressure dew point to further reduce the
temperature of the compressed air.
2. After that, the compressed air enters the evaporator and
exchanges heat with the refrigerant. The temperature of the
compressed air drops to 0 ° C - 8 ° C. The moisture in the air is
precipitated at this temperature, and the water condensed in the
compressed air is passed through the condenser. The oil and
impurities are separated and discharged through the automatic
drainer.
3. The dry low-temperature air enters the air to exchange heat with
the air exchanger, and the temperature rises and then outputs.
What problems occur when the solenoid valve coil is in use?
Everyone knows that solenoid valves play an important role in
industrial applications, and they have a long running time, and
sometimes there are some problems that make the equipment not
function properly. Most of this problem is caused by improper use
of the solenoid valve coil.
The solenoid valve coil may not be very secure at the time of
installation. During the operation of the device, the coil is in a
strong operation, so that the coil will fall, the solenoid valve
will not operate normally, or some may fall, and some may not. It
may cause the device to work for a while and not work properly,
both of which will delay the work. At this time, the operation is
relatively simple, and the coil can be firmly fixed on the solenoid
valve. There is also a case where the solenoid valve coil may be
burnt out due to excessive voltage, and the device may not operate
normally.
Therefore, when using the solenoid valve later, be sure to check
the position of the solenoid valve coil and do the correct
operation of the solenoid valve coil. This will ensure that the
solenoid valve will not cause problems.
Dimension of BB14542505 Solenoid Valve Coil :
Technical Data:
Attention:
1. This air suspension compressor pump solenoid coil is made of
high quality components.
2. Replaces the original air compressor solenoid coil of your car
and equal the original quality.
3. Please double confirm the compatibility as well as the OEM
number before purchasing.
4. Instruction is not included. Professional installation is
recommended.
Steps and methods for properly installing a solenoid valve coil:
1. Check if the solenoid valve and the selected parameters are the same, such as differential pressure, etc. If the error occurs, the solenoid valve coil will be burned out. Voltage fluctuations should be within the normal range and meet the rated voltage.
2. Before connecting the pipeline, flush the pipeline and remove the residual dirt in the pipeline. If there are residual stains, it will affect the normal use of the solenoid valve. To prevent this, a filter should be installed in the pipeline.
3. Install the solenoid valve coil of the solenoid valve vertically on the horizontal and ground pipes. If there is a special situation, it cannot be installed vertically. The appropriate solenoid valve should be ordered in advance, otherwise the solenoid valve will not work properly.
4. When installing, add a safety process and install a manual cutting valve to facilitate maintenance in case of failure.
5. Pay attention to the direction when installing, can not be reversed, installed in the direction indicated on the package, and can be reversed in some special cases such as vacuum.
6. If the water may be damaged by the medium, you must take appropriate protective measures or choose a solenoid valve with a waterproof hammer function.
7. The solenoid valve cannot be energized all the time, otherwise it will reduce its life. Note that normally open, normally closed solenoid valves cannot be used with care.
Product Features:
1. Using high quality wire which has UL approved; 2. Using high
quality permeablity magnetic material which contain low carbon;
3. Using high quality housing material like PA66, PBT, PPS, BMC and
so on.
4. Insulation class can be B, F, H, N, C;
5. Protection class can be IP65, IP67 & IP69K;
6. We also offer special coils like ex-proof coils, water proof
coils and so on.
7. If you have special requirement, pls feel free to contact us.
Focus on your demands, Offer you best solution:
√ Contact us if some points you have doubt
√ Contact us if somewhere need to change
√ Contact us if not the one you are looking for
√ Contact us if you are doing designing
Welcome to your any question and inquiry!