CA62T 2.5'' Right Angle Air Control Valve Baghouse Filter System


Dust collector pulse jet valve is controlled by solenoid coil, so the quality of the coil and the proper use of the coil will determine the operation of the valve. The main reasons for the solenoid valve coil to burn out is that the coil temperature is too high, and there are several reasons:

1: The actual voltage fluctuation is too large and exceeds the rated voltage range.

2: The starting power of the coil is not enough, so that the solenoid valve is always open, the coil heats up for a long time, the temperature rises, and finally the coil is burnt.


Technical data of Right Angle Pulse Jet Valves:

Model No
CA15T
CA20T
CA25T
CA35T
CA45T
CA50T
CA62T
CA76T
Nonimal size
φ15
φ20
φ25
φ35
φ45
φ50
φ62
φ76
Port Size
G1/2''
G3/4''
G1''
G1 1/4''
G1 1/2''
G2''
G2 1/2''
G3''
Working pressure
0.3 to 0.8MPa
Temp. range
-5℃ to 55℃
Relative humidity
≤85%
Working
medium
Compressed clean air
Voltage
24VDC, 220VAC

Dimension of CA62T Goyen Type Pulse Jet Valve:


Video of CA62T Goyen Type Pulse Jet Valve:


Detail images of Goyen Type Pulse Jet Valves:


More Goyen Type Pulse Valve For You to Choose:


Threaded Type Immersion Type Dresser Nut Type Flanged Type

RCA Series Solenoid Coil Armature Assembly Pulse Controller


Installation:
1. Prepare supply and blowtube pipes to suit valve specification. Avoid installing valves underneath the tank.
2. Ensure tank and pipes are free from dirt, rust or other particulate.
3. Ensure supply air is clean and dry.
4. Mount valves to inlet pipes and blowtube to valves, ensuring no excess thread sealant can enter the valve itself.
5. Make electrical connections to solenoid or connect RCA pilot port to pilot valve (RCA valves only).
6. Apply moderate pressure to system and check for installation leaks.
7. Fully pressurise system.
8. Test fire and listen for proper actuation and crisp pulse noise.


Focus on your demands, Offer you best solution:


√ Contact us if some points you have doubt
√ Contact us if somewhere need to change
√ Contact us if not the one you are looking for
√ Contact us if you are doing designing


Welcome to your any question and inquiry!

China CA62T 2.5'' Right Angle Air Control Valve Baghouse Filter System supplier

CA62T 2.5'' Right Angle Air Control Valve Baghouse Filter System

Inquiry Cart 0