CA568 is Calinmeter's multi-jet wet / dry type, STS prepaid water meter. The meter works with a low power motor driven hydraullical ball valve and shuts off when water credits are used up. Non-return valve and double layer strainer is built within. The meter is immune to small particles such as dirt and pipe rust thanks to its dual strainer design. It is mechanically stable and secured, never be jammed. Accuracy never drops in dirty water operating environment.
The prepaid water meter works with a Customer Interface Unit (CIU) to be installed within consumer's house. Consumers buy recharge token for water units from the vendor's kiosk or through mobile money. The recharge token is a 20 digits' code which can be entered manually on CIU in house.
Customer can also toggle up meter' information or input history by entering short codes on CIU.
Calinmeter is pioneer of STS prepayment metering in China. We are number 47 STS Association member in South Africa. For water meter, our company has strong technical support and advanced system service, For further information, please contact us freely.
Features
a) Various sizes avaiable from DN15 to DN150
b) Brass / plastic meter avaiable on request
c) Backflow prevention
d) Up to 300 meters com range bw CIU and meter
e) Dual display : LCD and counter register
f) Up to 5 year battery life and battery is replacable
g) Shut off on tamper, magnetic, battery removal
h) Low credit alarm, low battery warning available
i) Life time Data storage in abscence of battery power
j) Wireless communication for AMR AMI setups ( on request for high end features)
Key benefits
1) Fast installation with no extra cost of wires
2) Integration with mobile money, mobile payment, easy cash back and cash-flow
3) Revenue protection and improved efficiency
4) FBU, overdraft, emergency unit setting
5) Detect non-revenue water in AMR setups ( on request)
6) Remote reading and valve control ( optional for AMR setups)
Specifications:
Nominal size | Dn | mm | in-line | ||
15 | 20 | 25 | |||
Maximum flow rate | Q4 | m3/h | 3.125 | 5.0 | 7.875 |
Ratio “R” | Q3/Q1 | 80 | 80 | 80 | |
Permanent l flow rate | Q33 | m3/h | 2.5 | 4.0 | 6.3 |
Transitional flow rate | Q22 | 0.05 | 0.08 | 0.126 | |
Minimum flow rate | Q11 | 0.031 | 0.05 | 0.0787 | |
Minimum reading | m3 | 0.0005 | |||
Maximum reading | 99999 |
Maximum Permission Error (MPE)
Q1≦Q≦,Q2 MPE =+ 5% Q2≦Q≦Q4, MPE= + 2% (For hot water metering, MPE=+ 3%)
Dimensions and diagram
Nominal size | Length | Width | Height | Thread |
mm | D | |||
15 | 165 | 101 | 124 | G3/4B |
20 | 195 | 101 | 124 | G1B |
25 | 225 | 101 | 124 | G5/4B |