Autoclave Class Tabletop Steam Autoclave Sterilizer For Lab

Brand Name:Medpharm
Certification:CE/ISO
Model Number:MDB-V Series
Minimum Order Quantity:1 pc
Delivery Time:30 working days after received your payment
Payment Terms:T/T in advance, LC AT SIGHT
Contact Now

Add to Cart

Verified Supplier
Address: B631, HUAFANG INTERNATIONAL MANSION, No.178 CHENGBEI STR., ZHANGJIAGANG, JIANGSU, PRC, 215600
Supplier`s last login times: within 48 hours
Product Details Company Profile
Product Details

Autoclave Class Table Top Steam Cheap Autoclave Sterilizer for Lab


Description

  • When double door autoclaves are placed into a BSL-3 or BSL-4 laboratory, several decisions should be reviewed by the lab planner and/or architect.
  • The penultimate result of the decision process should always be in favor of public and operator safety.
  • The type of science being performed in the laboratory dictates the design and space requirements for the facility as well as the equipment necessary to operate the facility safely and efficiently

.


Features

1. Adopting European N standard, with thermal vacuum and drying functions, it can be used for A-type hollow instruments and solid instruments. Thermodynamic vacuum guarantees elimination of cold air from the cavity and makes sure that reaches the optimal effect of sterilization.
2. Specially design for dental clinic field, it could sterilize 12 pieces hand piece at same time, simply and efficiently.
3. Microprocessor control, LED display and modularized panel for easy operation.
4. Automatic malfunction detection system makes easy maintaining.


Technical Chart


Model

Chamber Size

Overall Size

Steam

Water

Power

W*H*D mm

W*H*D mm

Kg/cycle

Kg/cycle

KVA

MDB-0.11V

400*400*700

1000*1800*1040

14

15

2

MDB-0.16V

400*400*1000

1000*1800*1340

16

20

2

MDB-0.20V

400*400*1300

1000*1800*1640

18

25

2

MDB-0.24V

600*600*670

1200*2000*1010

20

30

2

MDB-0.30V

600*600*840

1200*2000*1180

22

35

2

MDB-0.36V

600*600*1000

1200*2000*1340

25

40

2

MDB-0.45V

600*600*1250

1200*2000*1590

27

50

2

MDB-0.60V

600*600*1670

1200*2000*2010

30

60

3


Autoclave Piping And Components


Specifically designed for use with steam systems that demand the highest safety conditions. 316L grade stainless steel is used for the chamber, piping and fittings. The inner chamber walls have a mirror like polished finish (Ra < 10μm) to create a smooth surface.

Chamber Drain Valve Area


The chamber drain valve area is the coldest spot in the chamber. The BSL autoclaves resolve this problem by applying steam directly to the chamber drain valve area.

Hot-Well

The hot-well is a stainless steel water reservoir in which the feed water is heated to 80-90°C prior to entering the steam generator. The hot-well facilitates the removal of non-condensable gases out of water.


Safety Valve


A safety valve is fitted to the chamber. Steam blasts from the safety valve are captured and condensed in an expansion vessel (optional) and then decontaminated before discharge to drain. Any remaining gases are treated via a microbiological sanitary air filter (optional).


Diaphragm Valves


Separate diaphragm valves (optional) for steam to the jacket and chamber prevent contamination from entering the valve mechanism.


Tri-Clamp Fittings


Tri-clamp fittings provide uniformly smooth and crevicefree self-aligning joints for non-contaminating steam flows. They minimise the possibility of external contamination penetration through the valves and piping connection areas.


Separate Jacket And Chamber Connections


Separate jacket and chamber connections (optional) prevent contamination from entering the jacket. With this option the jacket is completely separated from the chamber.

Biological Seal


The bio-shield is a barrier whose purpose is to create a complete hermetic seal between the differently qualified zones, providing maximum biological containment between the zones. The bio-shield system meets BSL3 and BSL4 bio-safety levels using a combination of stainless steel plates and flexible neoprene wall seal to prevent micro-organisms from passing between zones.


Jacket Frame

A fully welded metal flange with threaded studs surrounds the jacket. A counter plate is attached to the flange using the nuts provided. Any necessary fittings for electrical connections pass through this section of the bio-shield via specially sealed conduits.

Wall Frame


A wall frame is built into the concrete wall of the building. Continuous neoprene sealing is used to seal the sterilizer completely in the aperture in the wall.



Brochure load down from here

Medpharm medical large steam autoclave brochure.pdf

China Autoclave Class Tabletop Steam Autoclave Sterilizer For Lab supplier

Autoclave Class Tabletop Steam Autoclave Sterilizer For Lab

Inquiry Cart 0