120-347Vac input intelligent microwave motion sensor with UL approval

Brand Name:Merrytek
Certification:UL, CUL
Model Number:MC606V
Minimum Order Quantity:300pcs
Delivery Time:1, Sample and small order: Within 5 working days after receiving your payment. 2, Bulk order: 3-4 weeks after receiving deposit.
Payment Terms:T/T
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen Guangdong China
Address: 101-1101, Building 17, Dianda Guyuan Industrial Park, Mashantou Community, Matan Street, Guangming District, Shenzhen
Supplier`s last login times: within 33 hours
Product Details Company Profile
Product Details

120-347Vac input intelligent microwave motion sensor with UL approval


1. Features

  • Built-in motion sensor & daylight sensor
  • On/Off, Step Dimming Function
  • Wide Input Voltage range 120/277/347Vac
  • 15m Max. Mounting Height
  • 1-10V & Synchronous Control Interface
  • Sensor parameter can be set via DIP switch.
  • 5 Year Guarantee

2. Parameters

InputOperating voltage108-382V AC 50/60Hz
Rated voltage120/277/347V AC 50/60Hz
Stand-by power≤1.0W
Surge testN—L: 1kV
OutputWorking modeON/OFF 1-10V dimming
Type of loadInductive or resistive
Load capacity

120V, 50/60Hz, 3.6A, ballast;

277V, 50/60Hz, 3.4A, ballast;

347V, 50/60Hz, 3.3A, ballast;

Max.surge capacity


30A (50% Ipeak, twidth =500uS, 230Vac full load, cold start); 60A (50% Ipeak, twidth =200uS, 230Vac, full load, cold start)
Dim interface1-10V Dimming1-10V 0.5mA @Max.
Sensor parametersOperating frequency5.8 GHz ±75 MHz, ISM band
Transmitting power0.5mW Max.
Hold time5S/30S/90S/3min/20min/+∞
Stand-by dim Level10%/20%/30%/50%
Stand-by Period0S/5S/5min/10min/30min/1h/+∞
Detection Area25%/50%/75%/100%
Daylight Sensor2Lux/5Lux /10Lux 25Lux /50Lux /100Lux /Disable
Detection RadiusRefer to detection pattern
Mounting height3-12m (Max.12m)
Detecting Angle150°(wall mounting) 360°(ceiling mounting)
Operating environmentOperating Temperature-35℃...+70℃ Humidity: 85% (non-condensing)
Storage Temperature/humidity-40℃...+80℃ Humidity: 85% (non-condensing)
Certificate StandardsSafety standardsUL 60730-1
EMC standardsFCC part 15
Environmental RequirementCompliant to RoHS
CertificateUL+CUL
OthersWiringPress-in terminals wire diameter: 10-24 AWG
IP RatingIP20
Protection ClassClass II
InstallationBuilt-in
Installation dimensionInch: 5.04 (mm: 128)
PackageBubble bag+ Clapboard+ Carton(K=A)
Net weight119g
Life time5 years warranty @Ta 277V/347V full load

Note

1. “N/A” means not available.

2. The detection range of the sensor is related to the moving speed and size of moving object, mounting height, installation height and angle, installation site, reflectors around the sensor etc. The data in the document is typical value and tested by a 165cm person in an open indoor area.

The detection range at wall mounting will be longer at ceiling mounting. Please reduce detection sensitivity at wall mounting or contact us to confirm the sensor data settings.


3.Function

1. On-off function (Stand-by Period“0s”)

2. 2-step dimming function (Stand-by Period“+∞”)

3. 3-step dimming function (Stand-by Period“5s/5min/10min/30min/1h”)

4.Dimension (mm)

Note: During installation, the microwave antenna should be exposed as shown in the figure to prevent metal from blocking and shielding the microwave signal.


5. Wiring


*The sensor is designed for connect one load only. Connect more than one loads may damage the sensor.


6. Structure


7. Detection pattern


1)Ceiling mounting

Height: 3m

Sensitivity: 100%/75%50%/25%

Height: 6m

Sensitivity: 100%/75%50%/25%

Height:9m

Sensitivity: 100%/75%50%/25%

Height: 12m(*)

Sensitivity: 100%/75%

Fast moving (Speed: 1m/s)

Fast moving (Speed: 1m/s)

Fast moving (Speed: 1m/s)

Fast moving (Speed: 1m/s)

Slow moving (Speed: 0.3m/s)

Slow moving (Speed: 0.3m/s)

Slow moving (Speed: 0.3m/s)

Slow moving (Speed: 0.3m/s)

*When installation height is 3 / 6 / 9 meters, movement signal can be detected at 25%/50%/75%/100% detection sensitivity. When at 12 meters, movement signal is only detected at 75% 100% sensitivity, no movement signal detected for 25%/50% sensitivity.


1)Wall mounting:

Wall mounted height: 2m

Sensitivity: 100%/75%/50%/25%

Fast moving (Speed: 1m/s)

Slow moving (Speed: 0.3m/s)


8. Dip switch settings


1. Detection Area

12
ONON100%
ON-75%
-ON50%
--25%

2. Hold Time

345
ONONON5s
-ONON30s
ON-ON90s
--ON3min
ONON-20min
VI---+∞

3. Stand-by Period

678
ONONON0s
-ONON10s
ON-ON5min
--ON10min
ONON-30min
VI-ON-1H

VII

---+∞

4. Daylight Sensor

1234
ONONONON2Lux
---ON5Lux
-ONON-10Lux
-ON-25Lux
-ON--50Lux
VION---100Lux
VII----Disable

5. Dimming brightness preset function

56
ONON50%
ON-30%
-ON20%
--10%

9. Initialization

1. On/Off function & 3-step dimming function: After power on, the sensor automatically turns on light at 100% brightness. After 10sec, it turns off the light. During the initialization, the sensor is not able to detect movement.

2. 2-step dimming function: After power on, the sensor automatically turns on light at 100% brightness. After 10sec, it dims the light to a low light level (set by stand-by dim level). During the initialization, the sensor is not able to detect movement.


10. Factory setting

Detection Area: 100%, Hold Time: 5S, Daylight Sensor: Disable, Stand-by Period: 0S,

Dimming brightness preset function: 10%


11. Application notice

1) The sensor should be installed by a professional electrician. Please turn off the power before installing, wiring, changing the setting of the DIP switch.

2) The sensor which installed in the plastic and glass lampshade will reduce the sensitivity.For every 3mm increase in thickness, the sensitivity will be reduced by 20%.

3) The dimming performance could be different from different 0-10v drivers.

4) The light sensitivity threshold is in a sunny environment, no shadow and ambient light diffuse reflection. Ambient lux level could be different in different environment, weather, climate, time-of-day and season.

5) The parameters of the sensor may need to be reconfigured in different installation environments. Please refer to the following instructions or contact the manufacturer.

6) This sensor is for indoor use only. It will affect the waterproof effect for outdoor use. Wind, rain, and moving objects around will cause false triggering.

7) The distance between any inductive sensors should be greater than 3m.

8) When the sensor is installed in a metal lamp, metal reflective surface, or a narrow enclosed environment, the microwave will be reflected repeatedly and cause false triggering. Please reduce the sensitivity or contact the manufacturer for technical support.

9) Do not place the sensor close to high-density objects such as metal, glass,concrete walls, etc, false triggering could happen.

10) Please ensure that there are no moving signals around the sensor, such as fan,DC motor, sewer pipe, air outlet, etc., the sensor may generate false trigger.

11) For a new installation environment, it is recommended to install and test 5pcs of products before batch installation.

China 120-347Vac input intelligent microwave motion sensor with UL approval supplier

120-347Vac input intelligent microwave motion sensor with UL approval

Inquiry Cart 0