UL Approved 120/ 277/ 347Vac input Automatic Dimming Motion Sensor


For more details, pls refer to as follows:

MC613V D 99 Spec 2023.03.18.pdf


【Product Feature】

  • With mini sensor detector, which does not block light
  • Low transmitting power, no harm to human
  • Support Remote Controller and DIP switch to adjust parameters
  • low side lobe; better adaptability to metal warehouse; Strong anti-interference ability
  • 0-10V match MS01 can achieve daylight harvesting function
  • Not affected by temperature, humidity, noise, dust etc.

【Function】

√ON-OFF function○Daylight harvesting
√2-step dimming○Daylight priority
√3-step dimming○High-low sensitivity
○override function○Grouping

【Product Information】

  • Dimension (Unit:mm)

bodyTpye A sensorTpye B sensor
Tolerance: ±0.3mm

Wiring: 712±5mm
  • Wiring, Function


Installation Instruction

Tpye A sensor

Tpye B sensor


Note

The sensor is allowed to be connected to one load only. The sensor may be damaged if connecting more than one load.

Sensor antenna should be above LED tray.


DIP Setting


【Detection Range】


【Parameter】

Input
Rated Voltage120/277/347VAC 50/60Hz
Stand-by Power≤1W
Surge Test1KV(L/N, EN61000-4-5)
Output
Output dimming Mode0-10VDC Dimming SignalON/OFF Signal
Load Capacity

@120VAC 3.6A Ballast @277VAC 3.4A Ballast

@347VAC 3.3A Ballast

Max. Surge Capacity50A (50% Ipeak, twidth =500us, 230Vac full load, cold start)
Dim interface
0-10V Dimming

< 50mA(Non-constant source)

10%(0.5-1V) 20%(1.9-2.1V) 30%(2.9-3.1V) 40% (3.9-4.1V)

Sensor Parameter
Operating Frequency5.8 GHz ±75MHz, ISM wave band.
Transmitting power1mW Max.
Detecting Radius

1m/s ≥2.5m. @ 3m ceiling mounting, 1m/s ≥4m @ 2m wall mounting

Test conditions : the product is set to 100% sensitivity, and there is no obvious occlusion in the room of 60㎡, 165cm person.

Mounting Height3-6m (ceiling mounting)
3db beam angle80°@XZ plane
96°@YZ plane
Environment
Operating Temperature-35~70℃
Storage Temperature-40℃~80℃, Humidity: ≤85%(Non-condensing)
Certificate Standard
CertificateUL, CE, RED
Environmental RequirementCompliant to RoHS 2.0, Reach
Safety StandardsUL60730
IP RatingIP20
Protection ClassClass II
Other
WiringPress-in terminals wire diameter: L /N /L’: 18AWG +/-Dimming port: 22AWG
InstallationBuilt-in
PackageClapboard + Carton(K=A)
Net Weight120±5g
Lifetime5 years warranty @Ta 230V

Remote


【Initialization】

  • Switch function/three-stage dimming function: the light will be turned on 100% brightness by the initial energizing sensor, and will be turned off after 10 seconds. During initialization, no external motion sensing signal will be detected.
  • Two-phase dimming function: the light will turn on 100% brightness in the initial energizing sensor, and turn to low brightness 10 seconds later (the brightness set by stand-by dim level). During initialization, no external motion sensing signal will be detected.

【Default setting】

Sensitivity: 100%, Hold time: 8s, Daylight sensor: Disable, Stand by period: 0s, Stand by DIM level: 10%


【Application Notice】

  • Sensor should be installed by a professional electrician. Please turn off power before installing, wiring, or setting the DIP switches.
  • Microwaves cannot penetrate metal. Do not place product in a closed or a half-closed metal lamp. Neither metal nor glass is not allowed to cover above the product. If antenna needs to pass through the metal plate, please ensure that the top of sensor is close to the metal plate.
  • Sensitivity area is related to moving speed of objects, size of moving objects, mounting height, mounting angle, working environment, reflecting materials and etc.. Given detecting area is typical value that was measured by 165cm high testers in an indoor open environment.
  • The daylight thresholds are measured on a sunny day without shadow and in an ambient light diffuse reflection status. Different environment and climate cause different brightness values that daylight sensor measures.
  • The installation spacing between sensors is recommended to be greater than 3m, and the installation spacing between sensors and routers is recommended to be greater than 2m.
  • Sensor should not be covered or hided by metal, PCB, LED tray etc..The spacing between the sensor antenna and surrounding materials should be greater than 5mm. There should be no metal or PCB tracks near the sensor antenna, above or below it. The recommended thickness of cover is 2mm, and keep the spacing between the sensor antenna and cover is greater than 3.2mm.
  • Vibration signals will be regarded as moving signals to trigger sensor. Installing sensor should be away from the object that vibrates for a long time, such as large metal equipment, pipes, air conditioning outlets, exhaust vents, smoke exhaust machine ports, shaking fans, etc. Pets in detecting area may cause false trigger.
  • The antenna surface of microwave module should be away from input AC, output DC, rectifier bridge, transformer, switch tube and other high-power devices to avoid high frequency signals affecting the normal operation of microwave sensor’s antenna.
  • Sensor is for indoor use only. The waterproof effect for outdoor or half-outdoor use will be affected. Wind, rain, and moving objects may cause false triggering.
China UL Approved 120V / 277V / 347Vac input Automatic Dimming Motion Sensor supplier

UL Approved 120V / 277V / 347Vac input Automatic Dimming Motion Sensor

Inquiry Cart 0