Microwave Motion Sensor UL Approved Ultra-Small Size Super 5.8GHz Frequency MC090S U

Brand Name:Merrytek
Certification:UL
Model Number:MC090S U
Minimum Order Quantity:100PCS
Delivery Time:1, Sample and small order: Within 5 working days after receiving your payment. 2, Bulk order: 3-4 weeks after receiving deposit.
Payment Terms:T/T
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen Guangdong China
Address: 101-1101, Building 17, Dianda Guyuan Industrial Park, Mashantou Community, Matan Street, Guangming District, Shenzhen
Supplier`s last login times: within 33 hours
Product Details Company Profile
Product Details

Microwave Motion Sensor UL Approved Ultra-Small Size Super 5.8GHz Frequency MC090S


1. Features

  • Microwave motion detection version.
  • Eight DIP switch setting, distance, time, daylight sensor, multi-speed adjustable.
  • Ultra-small mounting size, multiple mounting options, support for top and bottom mounting options.
  • Super cost-effective, support a variety of lamps,tri-proof lamps, ceiling lamps.
  • The infrared sensor is used to filter out the light sensor, and the light sensitivity value is more accurate, and is not affected by cloudy and sunny days.
  • Low impedance 5.8G antenna for superior immunity to interference.

​2. Parameters


InputOperating Voltage Range105-300VAC 50/60Hz
Rated Voltage120-277VAC 50/60Hz
No-load Power≤1.0W
Stand-by Power≤0.5W
Surge TestBetween L and N: 1KV
OutputWorking ModeON/OFF
Type of LoadResistive or Capacitive
Load Capacity800W (Resistive) or 400W (Capacitive)
Load surge current30A relay - 30A (test twidth 500us @230Vac at 50% Ipeak, cold start at full load) or 60A (test twidth 200us @230Vac at 50% Ipeak, cold start at full load)
SensorOperating Frequency5.8 GHz ±74.9 MHz.ISM wave band
Transmitting power0.5mW Max.
Hold time5S/30S/60S/3min/5min/10min/20min/30min
Detection Area100% / 75% / 50% / 25%
Daylight Sensor2Lux/10Lux/25Lux/50Lux/Disable
Detecting Radius4-7m (Installed at 3m high )
Mounting Height2.5-6 m(Suction Top Installation)
Detecting AngleCeiling mount 150°

Operating

Environment

Operating Temperature-20℃…+60℃ Humidity: 85% (non-condensing)
Storage Temperature-40℃…+80℃
Certificate StandardsSafety standardsEN61058-1, EN61058-1-2
EMC standardsEN55015, EN61547, EN61000-3-2, EN61000-3-3
Environmental RequirementRoHS
CertificateUL
OthersInput/output terminal specifications0.5-0.75mm2
IP RatingIP20
Protection ClassClass II
InstallationBuilt-in installation
Dimension62*36*25mm
PackageBubble bag + partition + outer box (K=A)
Net Weight36g
Lifetime5 years warranty@Ta 230V full load

Note

1. “N/A”means not available.

2. Detection area is effected on volume of motion object and motion speed. The detection area is tested by a 165cm height person and walking speed is 0.5m/s.

3. Function​

On/OFF Function


4. Dimension (mm)

5. Wiring

*The sensor is designed for connect one load only. Connect more than one loads may damage the sensor.


6. Structure


7. Radiation Pattern

Ceiling mounting


Ceiling mounted height: 3m

Sensitivity: 100%/75%/50%/25%

Ceiling mounted height: 6m(*)

Sensitivity:100%/75%/50%

Normal moving (Speed:1m/s)

Normal moving (Speed:1m/s)

Slow moving (Speed 0.3m/s)

Slow moving (Speed: 0.3m/s)

*50%,75%,100% detection sensitivity is workable when installed at 6m mounting height. Only 25% sensitivity is not able to detect motion signal.


Wall mounting:

Wall mounted height: 2m

Sensitivity: 100%/75%/50%/25%

Normal moving (Speed:1m/s)

Slow moving (Speed 0.3m/s)


8. Function Dialing Settings

Detection Area

12

ONON100%

ON

-

75%

-

ON50%

-

-

25%

Hold Time

345

ONONON5S

ONON-30S

ON-ON1min

IV

ON--3min

V

-ONON5min

VI

-ON-10min

VII

--ON20min

VⅢ

---30min

Daylight Sensor

678
ONONON2Lux
ONON-10Lux
-ON-25Lux
IVON--50Lux
V---Disable

*When set to Disable gear, the sensor will turn on the light as long as the motion of the object is detected, regardless of whether the illumination is adequate or not.


9. Override Function

Power off, quick switch ON/OFF sensor 3 times (ON-OFF-ON-OFF-ON) within 2sec to override sensor function. Lights will blink 3 times and then switch ON all the time. Power off and on again to recover sensor function.


10. Initialization

After power on, the sensor automatically turns on light at 100% brightness. After 10sec, it turns off the light. During the initialization, the sensor is not able to detect movement.


11. Factory settings

Detection Area: 100%, Hold Time: 5S, Daylight Sensor: Disable


12. Use Caution

1. Be sure to cut off the power supply before installing or adjusting the setting of the dial switch.

2. The microwave cannot pass through the metal, make sure there are no metal above the sensor.

3. It has to be at least 3.5mm away from metal around the microwave antenna. It is not allowed to place antenna and metal on the same horizontal.

China Microwave Motion Sensor UL Approved Ultra-Small Size Super 5.8GHz Frequency MC090S U supplier

Microwave Motion Sensor UL Approved Ultra-Small Size Super 5.8GHz Frequency MC090S U

Inquiry Cart 0