Add to Cart
Relay Output vehicle access control system Single vehicle inductive loop presence detector
About loop detectors
Loop detectors are used wherever vehicles have to be detected, for
example: monitoring and safe guarding access ways or counting
vehicles. The output signal can be used for controlling door and
gate drive mechanisms, operating barriers, controlling traffic
light systems in car parks or activating card dispensers in car
parks.
SINOMATIC loop detector with direction detecting function that can
be used to statistics the vehicle flux. The principle is based on a
change in the inductance within the loop which is caused by the
metallic components of passing vehicles. The changes are picked up
and evaluated by a microprocessor. Ease of use thanks to automatic
calibration when the operating voltage is applied.
Technical Data
Power Consumption: 4.5VA
Output relays: 240V/5A
Operating temperature: -20°C to +65°C
Storage temperature: -40°C to +85°C
Signal holding time: Unlimited / limited when loop is permanently
covered 10 minutes
Sensitivity: Adjustable in 4 increments
Loop inductance: Total loop plus connection wiring: 50μH to
1000μH(Ideal is 100μH to 300μH)
Loop connection wiring: Maximum length 20 meters, twisted at least
20 times per meter
Main Features:
1) Reset Switch : The reset switch enables the detector to be
manually reset during commissioning and testing . This results in
the detector re-tuning the sensing loop and becoming ready for
vehicle detection ;
2) Selectable Pulse Time : This feature sets the length of time
that the pulse relay will be energized for 1 Second or 0.5 Seconds
;
3) Pulse Relay Selection : The Pulse Relay may be configured to
energize on detection of a vehicle or when the vehicle leaves the
loop ;
4) Sensitivity Boost : This feature sets the undetect level to
maximum sensitivity and is used to prevent loss of detection of
high-bed vehicles ;
5) Switch Selectable Sensibility : 4 sensitivity setting are
available on the switches to allow flexibility in configuration ;
6) Switch Selectable Frequency : 4 frequency settings are available
to prevent cross-talk between adjacent loops ;
7) Filter Option : This option is used to provide a delay between
detection of the vehicle and switchiing of the output relay . This
relay is normally used to prevent false detection of small or fast
moving objects ;
8) Permanent Presence Option : This feature ensure detection of the
vehicle will be maintained when the vehicle is parked over the loop
for extended periods .
Detail image
Technical parameters of Loop Detector
Power supply | 230V AC 115V AC 24V DC/AC 12V DC/AC |
Frequency range | 20KHz ~ 170KHz |
Sensitivity | Adjustable in 4 increments |
Reaction time | 10ms |
Channel | Single |
Operating temperature | -40ºC ~ +80º |
Relative humidity | <90% |
Environmental compensation | Automatic drift compensation |
Output mode | electric relay |
Loop inductance | Ideal is 100μH to 300μH(Connection included) |
Size of Housing | 78x40x108 mm (L x W x H) |