Add to Cart
Laboratory Furniture Testing Machines , Cupboard Door Hinge Durability Tester
Description:
Link the furniture contains hinge with this tester,simulate in process of repeating open and close the
sliding door in daily use.Repeat it after a certain numbers,evaluate the hinge whether exists damage
or other effect of using.
It Can be used in installed products to test, connect various sliding door and side direction firmly, no
producing any acting force to effect the testing.
Check the moving part and adjust the speed between 0.25m/s~2m/s according to requirement.
Test device pull length and angle can be adjusted according to actual testing requirement. Adjustable
range 100mm~500mm, angle 0~90℃.
Opening and closing power can be displayed by auxiliary instrument
measurement. Time stop can be
adjusted when the drawer starts or stops. Can set the testing numbers.
The machine is elegant and beautiful, no moving parts reveals, easy to operate.
Equip with drawer and Cupboard door switching device.
Specifications:
Model | TNJ-026 |
Power | 1∮ AC 220V 50Hz 3A |
Open Angle | 90-120degree |
Counter | 0-9,99999 |
Air supply | 7kgf/cm^2or above stable air |
Weight | ≈85Kg |
Dimension(W*D*H) | 150x100x160cm |
Test speed | 10~18times/min adjustable |
Cylinder stroke | 800mm |
Beam Max.height | 1200mm |
1)Purpose of equipment
Durability machine tester for cabinet door base on BS EN standard and BIFMA
3)Technical specifications
ØThis machine use for open and close cabinet door and must to fulfill minimum needed as follow:
a.Power supply: single phase AC 220V.1KW
b.Compress air – 6 kg/cm²
c.AC motor – to control the height from 250- 1000mm
d.Pneumatic cylinder
-Double acting cylinder with magnetic switch
-Have a fixture to hold the door handle and open/close the door up to130˚
e.Control panel/ console consists of:
·ON/OFF switch button
·6-digits Electronic Predetermine Counter (EPC)
-The EPC will register every stroke of the cylinder up to six digits,
-Will stop the test operation to the preset stroke,
-The EPC will display the number of stroke achieved during the test,
-EPC also able to store the number of cycles when the power interruption take place and able to display the actual reading and continues counting when operation resumes
-The signal shall maintain until the counter is reset
Note: one stroke is counted as one cycle