Monitor Repairing GE Cardioserv Defibrillator External Paddle REF 21730403

Brand Name:GE
Model Number:cardioserv Defibrillator
Minimum Order Quantity:1 pcs
Delivery Time:within 1-3 business days
Payment Terms:T/T, Western Union,paypal
Place of Origin:Original
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou Guangdong China
Address: Room 206, Jin Hao Zhi Ying centre Buliding, Fengxin Road NO.1, Science avenue, Luo Gang District Guangzhou Guangdong China
Supplier`s last login times: within 21 hours
Product Details Company Profile
Product Details

Monitor Repairing GE Cardioserv Defibrillator External Paddle REF 21730403


  1. Patient Monitor Service Range
  1. Electrocardio patient monitor/ECG/placenta monitor/ repair and accessories selling;
  2. Chip level repair and selling; mainboard, power supply, ECG, oximeter, blood press, module etc. of Mindray and serious brands repair and selling;
  3. Patient monitor/electrocardiograph for leasing, maintenance, guarantee repair and training.
NO.BRANDMODELREPAIR PARTSNORMAL PROBLEM
1MP20Mainboard,Power Supply1,can not turn on;
2,blurred screen/Not normal screen display/starting up with logo;
3,Repeatedly restart;
4,can not identify module;
5,MSL Power supply overload;
6,Intermittent fault;
7,Touch screen fault;
2MP30Mainboard,Power Supply
3MP40Mainboard,Power Supply
4MP50Mainboard,Power Supply
5MP60Mainboard,Power Supply
6MP70Mainboard,Power Supply
7M3001AModule,Mainboard,PCB
8M3012AModule
9M3014AModule
10M3015AModule
11M3016AModule
12M3000-60002NIBP Module
13M3000-60003NIBP Module
14MP5Mainboard,Power Supply 
15VM4Mainboard,PCB1,can not turn on;
2,NBP fault;
16VM6
17VM8
18M4735AMainboard,Power Supply,Defibrillation plate1.Error code 1
2.Error code 1000
3.can not turn on
4.Mainboard failure
5.Error 20004
6. ECG error
19GEDASH1800Module,Mainboard1.133 error
2.can not charge
3.NIBP can not deflate
4.NIBP signal can not be measured
5.can not turn on
20GEDASH2500Module,Mainboard
21GEDASH3000Mainboard,DAS module1.Restar
2.NIBP can not be measured
3.Turn on errot
4.Black screen
5. NIBP fault
22GEDASH4000
23GEDASH5000
24GESOLAR8000IMainboard,SAM80 module,TRAM module1.Invalid keyboard
2.Repeatedly restart
3.Fail Self-checking
4.Cannot detect module
5.SAM module can not be measured
6.NIBP can not inflate
25GESOLAR8000MMainboard,SAM80 module,TRAM module
26Spacelabs91369,SL2700,91387,91393,91390Mainboard,module,PCB1. The blood oxygen interference
2. The ecg interference
3. The blood pressure 2003 error
4. Check module
5. Restart boot
6. Touch screen failure
7. Unable to boot
8. The power adapter failure
27MindrayT5Mainboard,MPM module1.Can not display the sensor
2.NIBP fault
3.ECG fault
4.Can not measure IBP
5.SPO2 errot
6.ECG initialization error
7.can not turn on
8.LCD errot
9.Long time to turn on
10.Mainboard failure
11. MPM module fault
28MindrayT6Mainboard,MPM module
29MindrayT8Mainboard,MPM module

Detailed introduction:
Selling and replacing for Electrocardiogram Monitoring/ Defibrillator/ EGG/ Fetal Monitor Repair and parts;
To detect and judge Chip level Mainboard, Power Supply, ECG PCB, SPO2 PCB,NIBP PCB, Display, Keyboard Plate, Parameter PCB, Rotary Knob;
Selling and replacing all kinds of PCB, Power Supply, ECG PCB, SPO2 PCB,NIBP PCB, Display, Keyboard Plate, Parameter PCB, Rotary Knob;
Monitor/ Electrocardiograph for renting, maintenance, guarantee repairing and training.
Included brands: GE, , Spacelabs, Siemens, Mindray, ZOLL, Endoscopy, Tyco, NIHON KOHDEN, , Promeco etc.

China Monitor Repairing GE Cardioserv Defibrillator External Paddle REF 21730403 supplier

Monitor Repairing GE Cardioserv Defibrillator External Paddle REF 21730403

Inquiry Cart 0