Add to Cart
NP-C-500-595 99.9995% Nitrogen Gas Generator Psa Nitrogen Generation for Chemical
NP-C-500-595 99.9995% nitrogen generator equipment / system for Chemical PVC PET PP production
PSA nitrogen generator
1) N2 Purity: 99-99.9995%
2) N2 Flow: 3-3000Nm3/h
3) N2 Pressure: 1-8 bar(adjustable)
4) SIMENS PLC Controller
Good Quality Nitrogen Generator
1) Computer-aided operation
2) Simple technical design
3) Easy maintenance
4) Low energy consumption
2.Features
(1)The electrolysis separation pool is made of stainless steel,in
which the liquid storage, nitrogen generated and deoxygenating can
be proceeded at the same time, and the electrolyte is circulated
unblocked.
(2)Because of the big electrolysis area and the low temperature of
the electrolysis pool, the output nitrogen is of big amount and
high purity.
(3)Equipped with the device that prevent the returning of the
liquid, the instrument is guaranteed no liquid returning phenomenon
during operation.
(4)Equipped with over-voltage proof and over-current proof device,
the instrument is safe and reliable.
(5)The instrument can be used continuously or disconnectedly with
long service life, stable performance such as flow and purity.
(6)The flow is visualized and convenient for user to check because
it is tracked automatically and displayed in digital.
(7)The experiment work becomes more convenient because of the small
volume, light weight, reasonable structure and easy operation of
the instruments.
3.Operating Method and On-line
(1)First, please check whether there is unusual phenomenon such as
the serious damage on the surface or inside of the instruments
caused from transportation. And then check whether the fittings are
complete according to the manual.
(2)Compounding the electrolyte: Dilute 130g KOH with distilled
water of 450ml. After cooling, fill the solution into the liquid
container of 2 liters in the upper of the instrument. Then fill
distilled water into the container until the liquid surface reaches
to the level of 1.8 L.
(3)Screw the sealing cap off on the output exit on the back board
of the instrument, then connect the
pipeline of the external diameter of 3mm with the air origin (the
pressure of air origin must be ≥0.4MPa) and assure it sealed.
(4)Tighten the sealed cap to make it not leak, then turn on the
instrument. If the display of pressure is 0. 5MPa, and the digital
LED display of flow is “000” or close to “000” after started the
machine for a few minutes, it shows the instrument is normal;
Otherwise it shows the instrument leaks. In the case of leakage,
check the instrument with suds and exclude from leaking trouble.
(5)If the instrument is normal, turn off the power, and take down
the sealed cap of output exit. Connect the pipeline of the external
diameter of 3mm with the instrument, and assure there isn’t any
leakage, then hydrogen can be supplied normally.
(6)After operating, you need to switch off the power in time. While
using it again, you just need to switch
it on.
4.Notice
(1)Observe the discolor silica gel from the side, and replace the
old gel if needed. While replacing, switch off the power first.
After the display of pressure has been zero, screw off the
desiccator clockwise, take it out and made it upside down, then
screw off the upper cover counterclockwise and replace the discolor
silica gel. Finally, install them in negative direction and assure
it sealed.
(2)The automation of control system of the instrument is in high
level. The nitrogen will blow to clean the decontamination chamber
and pipeline system. With automatically emptying function, it can
discharge air before generating nitrogen. The process generally
lasts for 10 minutes. So the instrument will generate high purity
nitrogen in 10 minutes after working.
(3)The LED display value is only for reference because it is
converted from the electrolytic electric current. Because the
hydrogen flows out after the buffering of the purifying tube, the
output flow is relatively steady. So it’s normal if the flow
display has a extension of ±10 in tens digit.
(4)It is distilled water but not KOH that is consumed while the
operating of the instrument. So only distilled water should be
supplemented if needed to assure the electrolyte location is
between the upper and
lower line. It is proposed that the electrolyte should be replaced
every 6 or 7 months.
(5)When it’s found that the pressure is relatively lower or the
display value is relatively higher, it usually arises from leaking.
It should be checked by soap solution. Especially while replacing
the discolor silica gel, great attention should be paid to the
sealed place of hothouse and the instrument should be prevented
from leaking
Specifications:
Nitrogen Capacity/Flow rate: 3-3000Nm³/h
Nitrogen Purity: 95%-99.9995% (95%, 97%, 98%, 99%, 99.5%, 99.9%, 99.99%, 99.999%, 99.9995%)
No | Model | Capacity(Nm3/h) | Purity | Power(KW) | Overall size(mm) |
1 2 3 4 | PN-3-39 PN-5-29 PN-5-295 PN-8-295 | 3 5 5 8 | 99.9% 99.5% 99% 95% | 0.5 | 1800*1400*1500 |
5 6 7 8 | PN-5-49 PN-8-39 PN-12-295 PN-15-29 | 5 8 12 15 | 99.99% 99.9% 99.5% 99% | 0.5 | 1800*1400*1800 |
9 10 11 12 | PN-10-49 PN-15-39 PN-25-295 PN-30-39 | 10 15 25 30 | 99.99% 99.9% 99.5% 99% | 0.5 | 2000*1700*2250 |
13 14 15 16 | PN-15-49 PN-22-39 PN-35-295 PN-45-29 | 15 22 35 45 | 99.99% 99.9% 99.5% 99% | 0.5 | 2100*1800*2200 |
17 18 19 20 | PN-20-49 PN-30-39 PN-50-295 PN-60-29 | 20 30 50 60 | 99.99% 99.9% 99.5% 99% | 0.5 | 2200*1800*2200 |
21 22 23 24 | PN-30-49 PN-45-39 PN-75-295 PN-88-29 | 30 45 75 88 | 99.99% 99.9% 99.5% 99% | 0.5 | 2400*1900*2200 |
25 26 27 28 | PN-40-49 PN-60-39 PN-100-295 PN-120-29 | 40 60 100 120 | 99.99% 99.9% 99.5% 99% | 0.5 | 2500*2100*2500 |
29 30 31 32 | PN-50-49 PN-70-39 PN-120-295 PN-140-29 | 50 70 120 140 | 99.99% 99.9% 99.5% 99% | 0.5 | 2600*2200*2850 |
33 34 35 36 | PN-60-49 PN-90-39 PN-160-295 PN-190-29 | 60 90 160 190 | 99.99% 99.9% 99.5% 99% | 0.5 | 2800*2200*2500 |
37 | PN-80-49 | 80 | 99.99% | 0.5 | |
38 39 40 | PN-120-39 PN-200-295 PN-250-29 | 120 200 250 | 99.9% 99.5% 99% | 0.5 | 3200*1400*2800 |
41 42 43 44 | PN-100-49 PN-140-39 PN-250-295 PN-290-29 | 100 140 250 290 | 99.99% 99.9% 99.5% 99% | 0.5 | 3500*1500*2800 |
... | ... | ... | ... | ... | ... |