photovoltaic system power cable 2×6.0mm² (PV1-F / H1Z2Z2-K) Solar Cable

Brand Name:Zion communication OR OEM
Certification:ISO, CE, RoHS, UL
Model Number:2×6.0mm² (PV1-F / H1Z2Z2-K)
Minimum Order Quantity:5 KM
Delivery Time:25 working days
Payment Terms:T/T, L/C
Contact Now

Add to Cart

Verified Supplier
Location: Hangzhou Zhejiang China
Address: NO.68,HUAQIAO ROAD, LIN'AN, HANGZHOU, ZHEJIANG, CHINA
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details
2×6.0mm² (PV1-F / H1Z2Z2-K)
(NO.7194104)
General characteristics:

Appllcation:
Specifically designed to connect photovoltaic system components inside and outside buildings
and facilities under high mechanical demands and extreme weather conditions.
Cable Construction:
Conductor
Metarial:Tinned annealed copper
Area(mm²) :2×6.0
Construction(N/mm) :84/0.30
Conductor(Dia./mm) :3.17
Insulation120℃ XLPE
Standard thickness (mm) :0.75
Standard diameter (mm) :4.67±0.1
Jacket120℃ XLPE, Black
Standard thickness (mm) :1.05
Outer diameter (mm) :(7.0±0.2)×(14.5±0.2)
Weight rated102.6
MakingZION COMMUNICATION PV1-F / H1Z2Z2-K 2x6.0mm²
UV Res DC 1.5KV AC 0.6/1KV SOLAR CABLE
Package:
BOX (art.code ZC-100-2×6.0mm/ZC-500-2×6.0mm)
Size: 310x 310x100mm
PALLET (art.code ZC-100-100-2×6.0mm)
Size: 1100x1100mm
Amount of boxes on one pallet:
Weight of total pallet:
Cable length pallet:
Electrical properties
Nominal Voltage:PV1-F: DC 1.0KV AC 0.6/1.0KV
H1Z2Z2-K: DC 1.5KV AC 1.0/1.0KV
Ambient Temperature:-40℃~+90℃
Max.Temperature at conductor:+120℃
Service life:25 years ( -40~+90℃)
Voltage:600/1000V
Temperature:-40~90℃
Conductor resistance (20℃):3.39Ω/km
Insulation resistance (70℃):≥1000 MΩ/km
Withstand voltage(V/5min)AC6500
Speak voltage(V/5min)AC6500
Min bending radius(mm)4*D
Main performance parameter of finished cable
Voltage test of finished cable
Min.time of dipping in water≥1(h)
Testing voltage (AC)6500(V)
Min.voltage applying time at one time5(min)
Test resultno breakdown
Sheated surface resistance
Length of specimen:250mm
Test result≥109Ω
Penetrate the insulation resistance
Temperature20℃
Test result≥1014Ω
High temperature stress
Temperature140℃
A: with 1.2 Voltage testA: No breakdown
B: deep pressureB: Wall thickness 50%
Damp-heat test
Temperature90℃
Humidity0.85
Aging before and after the tenslle strength of Change≤30%
Aging before and after the elongation at break of Change≤-30%
Acid-alkali Resistance
Min.time of dipping in168h
Aging before and after the tensile strength of Change≤-30%
Elongation≥100
Low-temperature bending
Temperature-40℃
Time16h
Test resultNo crack
Ozone resistance
Ozeone concentration %(200±50)x10-6
Time72h
Test resultNo crack
Heat schrinkable jacket test
Test result≤2%
Flame retardant-Vertical burn
Flxture on the lower edge from the starting point and carbonization≥50mm
Burning fuel downward from the lower edge of bottom fixture≤540mm
Halogen content of non-metallic materials
Test result
Chlorine and bromine contentHCL≤0.5HBr≤0.5%
Fluoride contentF≤0.1%
The inner layer of insulation and sheath of the mechanical properties
Test result
Aging before tensile strength8.0N/mm²
Aging before elongation1.25
Aging before and after the tensile strength of change-30%
Aging before and after the elongation at break of change-30%
Hot extension
Temperature200℃
Test result-The inner layer of insulation and sheath
Elongation under load≤100%
Elongation after unloading≤25%
China photovoltaic system power cable 2×6.0mm² (PV1-F / H1Z2Z2-K) Solar Cable supplier

photovoltaic system power cable 2×6.0mm² (PV1-F / H1Z2Z2-K) Solar Cable

Inquiry Cart 0