Doppler In Line Pipe Type Ultrasonic Flow Meters For Waste Water Treatment

Brand Name:Purescience
Certification:ISO14001-2000/ISO9001-2008/GB/T28001/MC01010429
Model Number:YE-TUF2000FP
Minimum Order Quantity:5 sets
Delivery Time:3 weeks
Place of Origin:China
Contact Now

Add to Cart

Active Member
Location: Shanghai Shanghai China
Address: Room 811 Build 143, No. 1399 Husong Road, Shanghai, China
Supplier`s last login times: within 25 hours
Product Details Company Profile
Product Details

Doppler In Line Pipe Type Ultrasonic Flow Meters For Waste Water Treatment


Principle of operation

This doppler inline ultrasonic flow meter, employs the frequency shift, that's the Doppler Effect, of an ultrasonic signal when it is reflected by suspended particles or gas bubbles (can be discontinusely) in motion. A metering technology uses the physical phenomenon of a sound wave which changes frequency when it is reflected by the moving discontinuities in a flowing liquid. The ultrasonic sound is transmitted into a pipe with flowing liquids, and the discontinuities reflect the ultrasonic wave with a slightly different frequency that is directly proportional to the rate of flow of the liquid (Figure 1). Current technology requires that the liquid contain at least 100 PPM of 100 micron or larger suspended particles or bubbles.


Data sheet

ItemsPerformance & Parameter
ConvertorPrincipleTransit-time ultrasonic flow meter
Accuracy+ 1%
Operation4 keyboards operation
Output signal1 channel 4-20mA, resistance 0-1K , accuracy 0.1%
1 way OCT pulse (Pulse width: 6-1000ms, default: 200ms)
1 channel relay output
Input signal3 way 4-20mA, accuracy: 0.1%, (temp., pressure, level)
Temperature transducer Pt100, heat / energy measurement
CommunicationGalvanic isolation RS485, software upgrade by PC, MODBUS
Signal cableTwisted-pair cable, 50m; RS485, transmission distance 1000m or above.
Connect portPipe materialSteel, stainless, cast iron, copper, cement, PVC, aluminum, etc
Pipe Dia15 - 6000 mm
Straight pipeUpstream: 10xDia, or downstream: 5xDia, and 30xDia from pump
MeteringLiquid type

Single sonic wave transmittable liquid, such as municipal water, cooling

water,

seawater water, waste water, pure water, Sewage with particle content, such

as oil, crude oil, lubrication oil, diesel oil, fuel oilChemicals, petrochemicals,

heating, ventilation ,air conditioner, power plants,

Temperature-30-160℃
TurbidityUp to 10000 ppm and less bubble
Flow velocity0-7 m/s
Work environmentTemperatureConvertor: -20-60 ℃, Transducer: -30-160℃
HumidityConvertor: 85%RH, Transducer: submersible up to depth 2m
Power supplyDC8-36V or AC10-30V / 1.5W
DimensionConvertor: 95*95*35mm

Features:

  • Non-Intrusive, transducer for Most Pipes from DN32 to DN6000mm
  • Inline pipe type , insertion type or clamp on probe transducer for options
  • Wide Measuring Range of 0.05 to 9 mps
  • ±2% of Calibrated Span Accuracy
  • Configuration and Total Stored in SD
  • Protection IP65 for housing, IP68 for transducer

Metering Diagram

Flow measurement Heat measurement

Reference chart

Type

Model

Pipe dia (mm)

Temperature

Dimension (mm)

Clamp on

TS-2

DN15-100

-30-90℃

45x25x32

TM-1

DN50-700

-30-90℃

64x39x44

TL-1

DN300-6000

-30-90℃

97x54x53

Clamp on (high temperature)

TS-2-HT

DN15-100

-30-90℃

45x25x32

TM-1-HT

DN50-700

-30-90℃

64x39x44

TL-1-HT

DN300-6000

-30-90℃

97x54x53

Insertion type

TC-1

DN80-6000

-30-90℃

190x80x55

TC-2(lengthen)

DN80-6000

-30-90℃

335x80x55

Pipe type

G3 (π type)

DN15-25

-30-160℃


G2

DN32/DN40

-30-160℃


G3

DN50-6000

-30-160℃



Optional temperature transducer

Specification

Model

Dia

Temp.

Water cut

Accuracy

Clamp-on temp. transducer Pt100

CT-1

>DN50

-40-160℃

No

100+ 0.8℃

Insertion temp. Transducer Pt100

TCT-1

Yes

Insertion temp. Pt100 with pressure

PCT-1

No

Insertion temp.Pt100 for small pipe D

SCT-1

<DN50

Yes


Industries

  • Chemicals
  • Petrochemicals
  • Oil & Gas
  • Heating, Ventilation & Air Conditioning (HVAC)
  • Power Plants
  • Water treatment

Applications

  • Metering of cooling water
  • Demineralisedwater
  • Control of batching and blending operations
  • Mass flow measurement
  • Allocation measurement
  • District heating
  • Irrigation
  • Energy measurement

Model Selection

I

Model









YF

Electromagnetic flowmeter


TF

Turbine


VF

Votex


LX

Vane wheel


T

Ultrasonic



E/F display mode

E: compact/local display, F: remote display




Pipe Dia

Type (mm)




xxxx

10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300,

400, 500, 600, 800, 1000




Code

Accuracy




1

+ 0.5% FS




2

+ 1.0% FS




3

+ 0.2% FS





Code

Type





N

Converter: 12 / 24 VDC, pulse output





A

Transmitter: 24VDC, 4-20mA outpt





B

Intelligent, Lion battery, no local display





G

Smart, local display, 4-20mA output





C1

Smart, local display, RS485





C2

Smart, local display, HART






Code

Type






S

Carbon steel housing






L

Stainless steel housing






G

High pressure housing






HL

316L electrode






HTi

Titanium electrode






HTa

Tantlum electrode






HC

Hastelloy-C electrode






L1

Liquid media






L2

Gas media






P

Pressure compensation






T

Temperature compensation






PT

Pressure&Temp. Compensation






F

PTFE liner






X

Rubber liner

Sample: IYF-E-0100-1-C1-S-HL-L1-F,

Magmeter, local display, Dia: 100mm, + 0.5%FS, carbon steel housing, smart, 4-20mA outpt,

RS485, 316L electrode, liquid media meter, PTFE liner


Competitive Advantage:

  • Compliance to international standards: ISO9001-2008 / GB/T19001 / MC00000-044/507
  • CE approval
  • Strict process control
  • Advanced calibration equipment
  • Engineer team

Calibration

Work shop

China Doppler In Line Pipe Type Ultrasonic Flow Meters For Waste Water Treatment supplier

Doppler In Line Pipe Type Ultrasonic Flow Meters For Waste Water Treatment

Inquiry Cart 0