Handheld ultrasonic Ultrasonic Flow Meters / water flow meter with clamp on transducer

Brand Name:Purescience
Certification:ISO14001-2000/ISO9001-2008/GB/T28001/MC01010429
Model Number:TUF-2000H
Minimum Order Quantity:5 sets
Delivery Time:3 weeks
Place of Origin:China
Contact Now

Add to Cart

Active Member
Location: Shanghai Shanghai China
Address: Room 811 Build 143, No. 1399 Husong Road, Shanghai, China
Supplier`s last login times: within 25 hours
Product Details Company Profile
Product Details

Handheld ultrasonic flow meter with clamp-on transducer for closed pipe flow measurement


Product Description

The portable ultrasonic flow meter features the advanced Trans-Phase measuring technology, providing accurate and reliable flow velocity assessments in closed piping systems. It utilizes a non-invasive clamp-on transducer which is placed on the outside of a pipe. Within seconds, the backlit LCD provides stable flowrate readings in cubic meter per hour or meters per second. This product operates on metal or plastic pipes containing liquids with more than 100 ppm of 100 micron or larger suspended solids or entrained gases.


Features

  • High accuracy measurement: accuracy: +/-1%, linearity 0.5%, repeatability: 0.2%
  • Small size, light weight
  • Non intrusive measuring, clamp-on transducer, no pressure drop, no pipe disturbance
  • Wide measuring range, DN15 to DN6000mm
  • Large LCD display of: instantaneous flow, accumulated flow (positive, negative and net), velocity, work status, etc.
  • Built in data logger 24K, store over 2000 lines measuring data

Data sheet:

ContentParameters and performance
Main instrumentWork PrincipleTransit-time ultrasonic flow meter
Accuracy2% FS, Repeatability: 0.2%
Displaybacklit LCD, 4 line, 16 digit
Size200x93x33mm, 390g
OperationCompatible 16 key touch key board and simulation keyboard software
InterfaceInsulated RS232, update software, MODBUS
Outputsingle way OCT pulse
Signal cabletwisted pair cable, RS232 communication selection, (5m x 2)
Pipe conditionMaterialsteel, stainless steel, cast iron, copper, cement pipe, PVC, aluminum, glass fiber
DiameterDN15 - DN6000mm
Straight L10D upstream, 5D downstream, and min 30D away from pump
Liquid mediaMedia typewater, ultra pure liquid, solvents, and other fluid liquid
Media temp.Transducer: -30 to 90, (customized: -40 to 160)
Turbidity10000 ppm or below, less bubble
Flow rate0 - 10 m/s, bi-direction
Flow directionbi-direction flow
EnvironmentTemperatureMain unit: -20 - 60
Transducer: -40 - 160
Humidity85% RH
Power supplyAC 110 - 240V

Metering Diagram

Flow measurement Heat measurement

Reference chart

Type

Model

Pipe dia (mm)

Temperature

Dimension (mm)

Clamp on

TS-2

DN15-100

-30-90℃

45x25x32

TM-1

DN50-700

-30-90℃

64x39x44

TL-1

DN300-6000

-30-90℃

97x54x53

Clamp on (high temperature)

TS-2-HT

DN15-100

-30-90℃

45x25x32

TM-1-HT

DN50-700

-30-90℃

64x39x44

TL-1-HT

DN300-6000

-30-90℃

97x54x53

Insertion type

TC-1

DN80-6000

-30-90℃

190x80x55

TC-2(lengthen)

DN80-6000

-30-90℃

335x80x55

Pipe type

G3 (π type)

DN15-25

-30-160℃


G2

DN32/DN40

-30-160℃


G3

DN50-6000

-30-160℃



Optional temperature transducer

Specification

Model

Dia

Temp.

Water cut

Accuracy

Clamp-on temp. transducer Pt100

CT-1

>DN50

-40-160℃

No

100+ 0.8℃

Insertion temp. Transducer Pt100

TCT-1

Yes

Insertion temp. Pt100 with pressure

PCT-1

No

Insertion temp.Pt100 for small pipe D

SCT-1

<DN50

Yes


Industries

  • Chemicals
  • Petrochemicals
  • Oil & Gas
  • Heating, Ventilation & Air Conditioning (HVAC)
  • Power Plants
  • Water treatment

Applications

  • Metering of cooling water
  • Demineralisedwater
  • Control of batching and blending operations
  • Mass flow measurement
  • Allocation measurement
  • District heating
  • Irrigation
  • Energy measurement

Model Selection

I

Model









YF

Electromagnetic flowmeter


TF

Turbine


VF

Votex


LX

Vane wheel


T

Ultrasonic



E/F display mode

E: compact/local display, F: remote display




Pipe Dia

Type (mm)




xxxx

10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300,

400, 500, 600, 800, 1000




Code

Accuracy




1

+ 0.5% FS




2

+ 1.0% FS




3

+ 0.2% FS





Code

Type





N

Converter: 12 / 24 VDC, pulse output





A

Transmitter: 24VDC, 4-20mA outpt





B

Intelligent, Lion battery, no local display





G

Smart, local display, 4-20mA output





C1

Smart, local display, RS485





C2

Smart, local display, HART






Code

Type






S

Carbon steel housing






L

Stainless steel housing






G

High pressure housing






HL

316L electrode






HTi

Titanium electrode






HTa

Tantlum electrode






HC

Hastelloy-C electrode






L1

Liquid media






L2

Gas media






P

Pressure compensation






T

Temperature compensation






PT

Pressure&Temp. Compensation






F

PTFE liner






X

Rubber liner

Sample: IYF-E-0100-1-C1-S-HL-L1-F,

Magmeter, local display, Dia: 100mm, + 0.5%FS, carbon steel housing, smart, 4-20mA outpt,

RS485, 316L electrode, liquid media meter, PTFE liner


Competitive Advantage:

  • Compliance to international standards: ISO9001-2008 / GB/T19001 / MC00000-044/507
  • CE approval
  • Strict process control
  • Advanced calibration equipment
  • Engineer team

Calibration

Work shop

China Handheld ultrasonic Ultrasonic Flow Meters / water flow meter with clamp on transducer supplier

Handheld ultrasonic Ultrasonic Flow Meters / water flow meter with clamp on transducer

Inquiry Cart 0