Add to Cart
Electromagnetic flowmeter for slurry flow meter in sewage treatment plant DN100 Rubber liner
Product Description
The YF series electromagnetic flow meter can be with signal output of 4-20mA and/or pulse output. The flow transmitter can be mounted either integrally to the flow sensor or remotely. The transmitter features a three-line LCD that displays the flow total, flow velocity, flow rate percent of range, and alarm settings. A four-button keypad is used to change settings. There are 27 flow unit options to choose from programmed into the transmitter.
Key Features
Grounding
From flow meter housing terminal G to grounding by minimal 1.6mm2 copper cable, resistivity < 10 Ω.
Technical data
Product name | Electromagnetic flowmeter | ||
Product type | Local|compact display | Remote display | Signal converter |
Model | IYF-E | IYF-F | IRT |
Pipe Diameter (mm) | DN10-DN2000 | ||
Power supply | 100-240 VAC / 18-36 VDC | ||
Accuracy | + 0.5% | + 0.5% | + 0.5% |
Power consumption | <6w | <6w | <6w |
Enclosure rating | IP65 | IP68 | IP65 |
Liquid temperature | -25-120℃ | -25-120℃ | -25-120℃ |
Ambient temperature | -25-50℃ | -25-50℃ | -25-50℃ |
Relative humidity | 10-90% | 10-90% | 10-90% |
Meter ratio | 1:100 | 1:100 | 1:100 |
Flow direction | Bi-direction flow | Bi-direction flow | Bi-direction flow |
Communication | RS485 / Bacnet | RS485 / Bacnet | RS485 / Bacnet |
Signal Output | 4-20mA/Pulse/Frequency | 4-20mA/Pulse/Frequency | 4-20mA/Pulse/Frequency |
Accuracy
Pipe Dia (mm) | Velocity (m/s) | Accuracy |
3-20 | <0.3 | + 0.25% FS |
0.3-1 | + 1.0% Readout | |
1-15 | + 0.25% Readout | |
25-600 | 0.1-0.3 | + 0.25% FS |
0.3-1 | + 0.5% Readout | |
1-15 | + 0.3% Readout | |
700-3000 | <0.3 | + 0.25% FS |
0.3-1 | + 1.0% Readout | |
1-15 | + 0.25% Readout |
Model selection
Applicable metering liquid:
Non-applicable metering medial
Notice on the selection of local type and remote type:
Remote type means the transmitter and converter display are mounted
in different locations, it’s suggested to select
remote type in the following conditions:
I | Model | ||||||||
YF | Electromagnetic flowmeter | ||||||||
TF | Turbine | ||||||||
VF | Votex | ||||||||
LX | Vane wheel | ||||||||
T | Ultrasonic | ||||||||
E/F display mode | E: compact/local display, F: remote display | ||||||||
Pipe Dia | Type (mm) | ||||||||
xxxx | 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 400, 500, 600, 800, 1000 | ||||||||
Code | Accuracy | ||||||||
1 | + 0.5% FS | ||||||||
2 | + 1.0% FS | ||||||||
3 | + 0.2% FS | ||||||||
Code | Type | ||||||||
N | Converter: 12 / 24 VDC, pulse output | ||||||||
A | Transmitter: 24VDC, 4-20mA outpt | ||||||||
B | Intelligent, Lion battery, no local display | ||||||||
G | Smart, local display, 4-20mA output | ||||||||
C1 | Smart, local display, RS485 | ||||||||
C2 | Smart, local display, HART | ||||||||
Code | Type | ||||||||
S | Carbon steel housing | ||||||||
L | Stainless steel housing | ||||||||
G | High pressure housing | ||||||||
HL | 316L electrode | ||||||||
HTi | Titanium electrode | ||||||||
HTa | Tantlum electrode | ||||||||
HC | Hastelloy-C electrode | ||||||||
L1 | Liquid media | ||||||||
L2 | Gas media | ||||||||
P | Pressure compensation | ||||||||
T | Temperature compensation | ||||||||
PT | Pressure&Temp. Compensation | ||||||||
F | PTFE liner | ||||||||
X | Rubber liner | ||||||||
Sample: IYF-E-0100-1-C1-S-HL-L1-F, Magmeter, local display, Dia: 100mm, + 0.5%FS, carbon steel housing, smart, 4-20mA outpt, RS485, 316L electrodes, liquid media meter, PTFE liner |
Pipe Diameter, flow volume and product dimension
Dia | Flow volume (m3/h) | Product dimension (mm) | |||||
(mm) | Normal | Min | Max | L | D | H | H1 |
15 | 1.5 | 0.06 | 9.5 | 150 | 95 | 272 | 254 |
20 | 2.5 | 0.11 | 16.9 | 105 | 277 | 254 | |
25 | 3.5 | 0.18 | 26.5 | 115 | 283 | 254 | |
32 | 6 | 0.29 | 43.6 | 140 | 297 | 270 | |
40 | 10 | 0.45 | 67.8 | 150 | 307 | 280 | |
50 | 15 | 0.71 | 106.0 | 200 | 165 | 318 | 294 |
65 | 25 | 1.19 | 179.1 | 185 | 337 | 313 | |
80 | 40 | 1.81 | 271.4 | 200 | 352 | 326 | |
100 | 60 | 2.83 | 424.1 | 250 | 220 | 371 | 344 |
125 | 100 | 4.42 | 665 | 250 | 401 | 372 | |
150 | 135 | 6.36 | 954 | 300 | 285 | 431 | 403 |
200 | 250 | 11.3 | 1696 | 350 | 340 | 486 | 460 |
250 | 375 | 17.66 | 2650 | 400 | 395 | 547 | 511 |
300 | 540 | 25.43 | 3817 | 450 | 445 | 597 | 565 |
350 | 735 | 34.62 | 5195 | 505 | 657 | 620 | |
400 | 960 | 45.22 | 6785 | 500 | 565 | 717 | 675 |
450 | 1200 | 57.23 | 8588 | 550 | 615 | 757 | 727 |
500 | 1500 | 70 | 10602 | 600 | 670 | 817 | 782 |
600 | 2160 | 100 | 15268 | 780 | 917 | 782 | |
700 | 2950 | 138 | 20781 | 700 | 895 | 1027 | 1068 |
800 | 3850 | 180 | 27100 | 800 | 1015 | 1137 | 1157 |
Industrial applications
Chemical | Food & beverage | Paper mill |
Metallurgy | Environment protection | Hydraulic |
Mining | Stainless | Petroleum |
Pharmacy | Air conditioner | Effluent treatment plant |
Seawater desalination | Pharmacy | Water treatment |
Competitive advantage