Electrical FRC 4 Core Heat Resistant Cable 1.5mm - 800mm 90℃ Temperature

Brand Name:SHANCABLE
Certification:CE/KEMA/ISO/PCCC
Model Number:NH-YJV
Minimum Order Quantity:1000m
Delivery Time:As per schedule
Place of Origin:SHANGHAI,CHINA
Contact Now

Add to Cart

Verified Supplier
Location: Shanghai Hunan China
Address: No.7577 Hunan Road, Pudong New District. Shanghai China
Supplier`s last login times: within 35 hours
Product Details Company Profile
Product Details

Electrical FRC 4 Core Heat Resistant Cable 1.5mm - 800mm 90℃ Temperature

Cable Structure

Conductor : Class 1,2,5 Flexible Copper Conductor
Screen: Mica tape
Insulation: PVC or LSZH PO
Sheath:PVC: (Optional)
Rated Voltage : 450/750V


Standard :


IEC 60502,60331 IEC 60227, IEC 60331, IEC 601034, IEC60754 GB/T 12706-91 GB306.1-2001, GB/T18380.3-2001

CE, CCC, KEMA

Constructions

Conductor: Circular stranded copper conductor, conforms to IEC 60228 class 2

Insulation: XLPE/A

Inner Covering: LSOH

Sheath: LSOH , black

Note: Insulation color as per standards or customer requirement


Applications

Used for tall building, Hospital, Theatre, Power station, Metro Tunnel or Petrochemical Industry or other special place required for low smoke , zero halogen clean and safe cable.


Standards

International: IEC 60502, IEC 60227 IEC 60331, IEC 601034

China: GB/T 12706-91 GB306.1-2001, GB/T18380.3-2001

Other standards such as BS,DIN and ICEA upon request


Technical data

Rated voltage: 0.6-KV

Max. Conductor Temp.: normal (90°C), short circuit no more than 5 s (the highest temperature of conductor shall no more than 250°C )

Min. Ambient Temp.:The cable shall be pre heated if the ambient temperature is below 0°C

Min. Bending Radius: single core cable 20(d+D)±5%

Multi-core cable 15(d+D)±5%


Certificates

CE, RoHS, CCC, KEMA and more others at request


Nom. Cross-section of conductorInsulation ThicknessSheathApprox.ApproxMax. D.C. Resistance of Conductor (20°C)Test VoltageCurrent Rating
mm2mmThicknessO.D.WeightΩ/kmA.C
mmmmkg/kmkV/5minIn air(A)In soil(A)
1×1.50.71.87.78112.13.52233
4×1.50.71.814.424112.13.52027
4×2.50.71.815.42957.413.52635
4×40.71.816.53694.613.53445
4×60.71.817.84633.083.54357
4×100.71.820.96671.833.56077
4×160.71.823.49301.153.583105
4×250.91.827.113510.7273.5105125
4×350.91.829.517720.5243.5125155
4×5011.938.423800.3873.5160185
4×701.1243.233020.2683.5200225
4×951.12.247.343300.1933.5245270
4×1201.22.352.553740.1533.5285310
4×1501.42.558.366550.1243.5325345
4×1851.62.764.782460.09913.5375390
4×2401.72.973.1105690.07543.5440450
4×2.5+1×1.50.71.816.53137.412635
4×4+1×2.50.71.817.74244.613445
4×6+1×40.71.819.15353.084357
4×10+1×60.71.822.17601.836077
4×16+1×100.71.825.110711.1583105
4×25+1×160.71.82915560.727105125
4×35+1×160.91.931.419760.524125155
4×50+1×2512.13626890.387160185
4×70+1×351.12.241.137190.268200225
4×95+1×501.12.446.349030.193245270
4×120+1×701.22.55161650.153285310
4×150+1×701.42.755.874310.124325345
4×185+1×951.62.962.191920.0991375390
4×240+1×1201.73.168.8118600.0754440450

Operating characteristics

1, Long-term allowable operating temperature of cable conductor ≤70°C
2, Highest working temperature of cable in case of short circuit (the longest lasting time is not over 5s):≤300mm2 cable conductor ≤160°C, 300 mm2 cable conductor 140°C.
3, The laying temperature should over 0℃,Permissible bending radius of cable:for single core unarmored cable, should be no less than 20 times of its outer diameter ; for multi-core unarmored cable, should be no less than 15 times of its outer diameter
4, With flame-retardant property,ZA,ZB,ZC,ZD are 4 types
5, The product is applicable for AC 50 Hz transmission and distribution lines with rated voltage of 0.6/1KV


Packing and shipping


We are capable of meeting the most strict delivery schedules according to per purchase order. Meeting the deadline is always the top priority as any delay in the delivery of cable can contribute to overall project delay and cost overrun.
Cable is supplied in wooden reels, corrugated boxes and coils. Cable ends are sealed with BOPP self adhesive tape and non-hygroscopic sealing caps to protect the cable ends from moisture. The required marking shall be printed with a weather-proof material on the outsides of drum according to customer's requirement.

China Electrical FRC 4 Core Heat Resistant Cable 1.5mm - 800mm 90℃ Temperature supplier

Electrical FRC 4 Core Heat Resistant Cable 1.5mm - 800mm 90℃ Temperature

Inquiry Cart 0