PRODUCT INTRODUCTION
This product is an indoor combustion gas detector with high stability , hereinafter called detector, used for combustion gas leak detection. It uses highly stable semiconductor gas sensor with features of stable performance and low drift of sensitivity. When it senses combustion gas leak that reaches the set alarm level, it will give out alarm sound with red LED flashing. The detector is applied in indoor places where combustion gas leaks possibly happen.
FEATURES
● Detects Natural Gas/LPG
● Celling Mounted
● Highly Stable Semiconductor Gas Sensor
● Adopts MCU Processing
● Manual Test/Auto Reset Functions
● Auto Check Malfunction
● High Capacity Relay (3A/250V)
● SMT Manufacture Technology, High Stability
● Comply to GB15322.2-2003
Model NO. | JS-GD51NS-AC | JS-GD51NVS-AC | JS-GD51LC-AC | JS-GD51NC-DC | JS-GD51LC-DC | |
Operating voltage | AC110V or 220V | DC12V-24V | ||||
Gas species | Natural gas or LPG | |||||
Sensor | Semiconductor | |||||
Drivable accessaries | N/A | Solenid valve | N/A | N/A | N/A | |
Alarm level | 6%LEL(±3%LEL) of Natural gas | |||||
Alarm output | Sound & LED flash alarm | |||||
Sound level | ≥75dB/m | |||||
Installation | Ceiling mounted | |||||
Working environment | -10℃~+50℃,(≤95%RH No congelation) | |||||
Dimension | Φ122*40mm |
INSTALLATION
1. First identify your gas heavier or lighter than air. Heavier
gases: LPG etc. Lighter gases: natural gas, marsh gas, artificial
coal gas etc.
2. Choose a suitable installing position according to gas specific
gravity. Detecting heavier gases, installation height 0.3-1.0m from
floor , semi-diameter to gas source <1.5m; Detecting lighter
gases, installation height 0.3-1.0m from ceiling, semi-diameter to
gas source < 1.5m (refer to the following image).
3. Fix the attached base into a wall firmly with screws and hang
the detector.
4. Do not make it close to gas stoves when installing at home in
case it is roasted by flame. Neither places with heavy oil or smoke
that may cause false alarms or block the gas convection holes and
influence the detector sensitivity. Also it is can not be installed
near to exhaust fans, windows, doors, and places with great vapor
in bathrooms.
5. Connect the wires correctly according to the wire harness instructions. All wiring and installation must accord with the National and Local laws and criteria. Improper connection will cause the detector not alarm while gas leaking.
OPERATION INSTRUCTION
1. WIRING
Confirm the detector working voltage and output type by the label
in the detector reverse.
DC type detector: 9-24V DC.
AC type detector: 220V AC.
A 5-PIN wire harness is attached in the gift box.
NOTICE:
The detector can not have Relay output and Pulse output for
Solenoid valve simultaneously. Check the reverse label for the
detector output type and pay attention to connect the wires
correctly as per the connection instruction.
2. FUNCTION
2.1 Connecting the power, the power LED constant green on. fter the
buzzer gives out a Di sound, the circuit enters into warm-up state.
The red LED and yellow LED flash alternately during warm-up and
stop in about 3 minutes, which indicates that the detector enters
into normal working state. Test is forbidden during warm-up time.
2.2 When any combustion gas leak happens and reaches the alarm
level, the alarm LED flashes red and meanwhile the buzzer gives out
“Di...Di” sound. If the detector has output function, the relay
output will be activated or pulse signal will be sent out to shut
off the connected solenoid valves .
2.3 If an inside sensor failure occurs, the yellow LED constant on
and the buzzer long beeps. Switch off the power and contact your
dealer for maintenance. Do not take the detector apart privately to
prevent electrical shocks.
3. TESTING
3.1 The detector has a self-test button for checking if the LED and
the buzzer can work normally. When pressing the test
button, the red & yellow LED flashes alternately and the buzzer
gives out alarm sound and the output is activated if with the
function.
3.2 It is forbidden to test with a lighter directly toward the gas
convection holes. This will cause damage to the inside sensor.
Instead, gather the gas from the lighter into an empty plastic
mineral water bottle and release the gathered gas toward the gas
convection holes for testing.
FAILURE REASONS & SOLUTIONS
ALARM TREATMENTS
When the concentration of natural gas or LPG in ambient air reaches
or exceeds the alarm level, the detector will enter into constant
alarm state. Below treatments are advised:
1. Shut off pipe valves.
2. Do not plug or unplug electrical appliances.
3. Open windows to circulate air.
4. Inspect the gas leak reason and notify related departments in
time to deal with the leak by professionals. If it turns out a
false alarm, check if the installation position is improper.
NOTES
1. The detector is for combustion gases detection. It can not be
used to test CO etc. poisonous gases.
2. Correct power supply must be provided and the wires must be
connected right. It can not work without normal power supply.
3. Mild heat-up in housing surface is normal at working time.
4. Do maintenance as per this manual Periodically.
5. Vacuum the dirt in the detector surface every month.
6. Do not use cleansers or solvents to clean the detector.
Chemicals may cause permanent damage or transient pollution to the
sensor.
7. Do not spray air-freshers, hair gels, paints or other aerosols
near the detector.
8. To assure the detector sensitivity, the detector should be
inspected by a profession every year. If it fails to work, repair
or replace the detector asap.
9. The service life of the detector semiconductor gas sensor is 5
years. Replace the detector immediately when the service life
expires.
10. The detector can reduce accidents happening, but can not
guarantee 100% safety. For your safety, besides proper usage of the
detector, pay attention to build up safety conscious and take
preventive measures in daily life.