Very Low Noise, 24-Bit Analog-to-Digital Converter
FEATURES
APPLICATIONS
DESCRIPTION
The ADS1255 and ADS1256 are extremely low-noise, 24-bit analog-to-digital (A/D) converters. They provide complete high-resolution measurement solutions for the most demanding applications.
The converter is comprised of a 4th-order, delta-sigma (∆Σ) modulator followed by a programmable digital filter. A flexible input multiplexer handles differential or single-ended signals and includes circuitry to verify the integrity of the external sensor connected to the inputs. The selectable input buffer greatly increases the input impedance and the low-noise programmable gain amplifier (PGA) provides gains from 1 to 64 in binary steps. The programmable filter allows the user to optimize between a resolution of up to 23 bits noise-free and a data rate of up to 30k samples per second (SPS). The converters offer fast channel cycling for measuring multiplexed inputs and can also perform one-shot conversions that settle in just a single cycle.
Communication is handled over an SPI-compatible serial interface that can operate with a 2-wire connection. Onboard calibration supports both self and system correction of offset and gain errors for all the PGA settings. Bidirectional digital I/Os and a programmable clock output driver are provided for general use. The ADS1255 is packaged in an SSOP-20, and the ADS1256 in an SSOP-28.
ABSOLUTE MAXIMUM RATINGS
over operating free-air temperature range unless otherwise noted(1)
ADS1255, ADS1256 U | UNIT | ||
AVDD to AGND | −0.3 to +6 | V | |
DVDD to DGND | −0.3 to +3.6 | V | |
AGND to DGND | −0.3 to +0.3 | V | |
Input Current | 100, Momentary | mA | |
10, Continuous | mA | ||
Analog inputs to AGND | −0.3 to AVDD + 0.3 | V | |
Digital inputs | DIN, SCLK, CS, RESET, SYNC/PDWN, XTAL1/CLKIN to DGND | −0.3 to +6 | V |
D0/CLKOUT, D1, D2, D3 to DGND | −0.3 to DVDD + 0.3 | V | |
Maximum Junction Temperature | +150 | °C | |
Operating Temperature Range | −40 to +105 | °C | |
Storage Temperature Range | −60 to +150 | °C | |
Lead Temperature (soldering, 10s) | +300 | °C |
(1) Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. Exposure to absolute maximum conditions for extended periods may degrade device reliability. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those specified is not implied.