Add to Cart
Digital Ultrasonic Generator For Ultrasonic Cleaner External Control 600W 28Khz JM-600
Same series Generator with different power:
Model | Power control | Default frequency | Other Frequency | Double/Sweeping frequency |
JM-600 | 0~600W | 28 or 40KHz | 68/80/132/20KHz | Optional |
JM-1200 | 600~1200W | 28 or 40KHz | 68/80/132/20KHz | Optional |
JM-1800 | 1200~1800W | 28 or 40KHz | 68/80/132/20KHz | Optional |
JM-2400 | 1800~2400W | 28 or 40KHz | 68/80/132/20KHz | Optional |
Function and button instruction
Power switch: cut in or cut off input power; When switch stay at
“ON” and the light of switch is on, then the input power is normal.
Display and button: showing working condition and set timer for
generator
Power adjust knob:turning left is for weaker power,turning right is
for stronger power. Power can be adjusted through power adjust
knob.
High frequency output terminal:left side is positive,right side is
negative, wrong position is not acceptable.It will have possibility
for electric leakage or no output power if you connect the wrong
side.
PLC remote terminal:This terminal is optional and has two output
cable. You will only get output when the terminal is short circuit.
Power plug and power cord:connecting power through plug.Power will
be supplied to generator.
Fan:Cooling system for internal part of generator. It can ensure
the reliability of parts
Nameplate:showing main electrical parameter like frequency,power,
input voltage.
Please operate generator under these condition or it will damage
the generator.
Instruction of other function on generator
Frequency tracking:If the difference of Transducer frequency stay
at the range of +-1.5KHZ,generator can match the difference
automatically without adjusting frequency.
Current stable ring:The generator has stabilizing circuit loop so
Current will be stabilized at the named parameter (+-0.1A), no
matter at the condition of overload or the change of water
temperature and power supply. It is a key for stable cleaning.
There is EMI circuit in the generator and Power is adjusted by
phase-shifted fullbridge technology. So it can make the influence
from outside at lowest level. Comparing to traditional Thyristor
tuned circuit, it can totally solve the problem of serious surge
current and serious conduction disturbance and radiation
disturbance caused by surge current under 90 and 270 degree phase
position.