Add to Cart
2000 Gallon Ultrasonic Bath For Large Condenser With Heating Power 28KHz
Detailed Specification of this machine:
1 | Model | JP-1923ST | |
2 | Parameter | Function | Ultrasonic cleaning |
Ultrasonic Frequency | 28/40kHz (other frequency can be customized) | ||
Tank Material | SUS 304 (SUS 316 can be customized) | ||
Thickness of tank | 3mm | ||
Inner tank dimension | 3500*1600*1300mm | ||
Tank Capacity | 7280L | ||
Transducer | 936pcs | ||
Ultrasonic Power | 46800W | ||
Heating Power | 66000W | ||
Time setting of Ultrasonic | 0~99 hours | ||
Temperature setting | Room temperature ~ 95°C adjustable | ||
Drain value | Available | ||
Water inlet/outlet | Available | ||
Generator | 26 sets | ||
Generator power control | 1800W | ||
Generator shelf | Available | ||
Basket | Available | ||
Basket load | 2000KG | ||
3 | Packing | Overall size | 390*200*200cm |
Packing size | 400*210*210cm | ||
Packing detail | By wooden case(No logs, free of fumigation) | ||
N.W/G.W | 4000KG/4300KG | ||
4 | Power supply | 380V 3 phase; 220V 3 pahse; 415V; 600V | |
5 | Warranty | 1 year warranty for spare parts, all life technical support | |
6 | Certificate | CE, RoHS; FCC, REACH | |
7 | Lead time | 20~30 working days after deposit |
7 | Optional functions | Filtration cycle system | Available; capture dirty water, recycle clean water |
Lifting system for basket | Available; take the basket up and down | ||
Dunking system | Available; Speed up cleaning | ||
Bubbling | Available; need to connect air compressor | ||
Electrolysis | Available; For cleaning more complex structure mold | ||
Cooling system | Available; To cool down inflammable and explosive | ||
Constant temperature | Available; | ||
Roller barrel | Available; for clean coins and big quantity parts | ||
Anti-explosion electric box | Available; | ||
Deionized(DI) water | Available | ||
Double/Multi frequency | Available; 28/40/20/68/80/132KHz | ||
Other funtions | Negotiate via email |
Other size and capacity for reference:
Product show:
Cleaning effect show:
Skymen Cleaning Equipment Shenzhen CO., Ltd.
Ultrasonic Cleaning Machine for Condenser
The water chiller is prone to scale formation in the condenser pipe
after long-term use. If it is not treated in time, the scale will
affect the heat exchange effect and cause the condensing
temperature of the unit to increase, which in turn leads to a
decrease in the cooling capacity and an increase in the power
consumption of the unit. .
In general, the condenser of an industrial chiller should be
cleaned frequently.
Chemical cleaning method:
Chemical cleaning mainly uses cleaning fluid for cleaning. Firstly,
acid solution is used for cleaning, then alkaline solution is used
for neutralization and cleaning, and finally clean water is used to
rinse off acid and alkaline solutions.
1. A circulating pump and pipeline can be connected between the
cleaning liquid storage tank and the condenser to form a closed
loop, so that the cleaning liquid can be circulated continuously
for 12-24 hours to dissolve and fall off the sediment.
2. The cleaning fluid can be added to the cooling water system in a
certain proportion, and the cooling pump is turned on for 12-24
hours. The sediment layer is continuously dissolved and peeled off
by the chemical action and scouring action of the cleaning fluid.
However, this method requires a lot of cleaning potions, and the
cost is high.
3. Mix the cleaning liquid in a certain proportion, add it to the
condenser and let it stand for 5-10 hours to soften and dissolve
the sediment, drain the cleaning liquid, and rinse with clean
water.
The advantage of chemical cleaning is thorough descaling, reducing
the workload of workers, but the disadvantage is that the cleaning
liquid may cause corrosion to the condenser copper pipe, the waste
liquid discharge problem after cleaning, and the price of the
cleaning liquid is relatively expensive.
Physical cleaning method:
Physical cleaning mainly uses flexible shaft brush cleaning. The
flexible shaft is driven by the motor of the washing machine to
rotate. There is a nylon brush at the front of the flexible shaft.
When in use, the flexible shaft and brush are extended into the
copper tube of the condenser, and the brush is rotated at high
speed to remove the inside of the copper tube. The dirt is finally
rinsed with clean water. This kind of machine is called a gun
machine.
The advantage of physical cleaning is that it saves the cost of
chemical cleaning liquid, avoids the disposal of waste liquid after
chemical cleaning, and is not easy to cause corrosion of the
condenser copper pipe. The disadvantage is that the cleaning effect
is not good for hard scale and corrosion products with strong
adhesion. Good, and the cleaning operation is time-consuming and
laborious.
Two common methods for removing condenser scale in water chillers
Ultrasonic cleaning uses a combination of chemical cleaning and
physical cleaning
Inject water into the ultrasonic tank, add a certain proportion of
mild chemical cleaning agent, and immerse the entire condenser in
the ultrasonic cleaning tank. The ultrasonic high-frequency
oscillation can quickly peel off the dirt on the condenser without
causing any damage to the condenser