Add to Cart
GPON 1 x 8 Fiber Optic Plc Splitter Blockless Splitter Module With 0.9mm Cable Smf-28e G657
PLC Splitter is Based on the Planar Waveguide Technology.
It Provides a Low Cost Power Distribution Solution with Small Form Factor and High Reliability
Features
More pictures
cable input and outputs: 0.9mm tight or loose tube, white color
cable input and outputs: 0.9mm tight or loose tube, input yellow color, output white color, on customer request
Application
Specification
1×N PLC Splitter
Parameter | Unit | Value | |||||||||||||||||
Product Type | 1×2 | 1×3 | 1×4 | 1×6 | 1×8 | 1×12 | 1×16 | 1×24 | 1×32 | 1×64 | 1×128 | ||||||||
Operation Wavelength | nm | 1260~1650 | |||||||||||||||||
Insertion Loss | Typ. | dB | 3.6 | 6.0 | 7.0 | 9.2 | 10.3 | 12.2 | 13.6 | 15.8 | 16.6 | 20.1 | 24.5 | ||||||
Max. | 4.3 | 6.2 | 7.4 | 9.5 | 10.7 | 12.5 | 13.9 | 16.0 | 17.2 | 21.5 | 25.5 | ||||||||
Uniformity (Max.) | dB | 0.5 | 0.6 | 0.8 | 0.8 | 0.8 | 1.2 | 1.4 | 1.5 | 1.5 | 2.0 | 2.6 | |||||||
PDL(Max.) | dB | 0.2 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.5 | 0.8 | |||||||
TDL(Max.) | dB | 0.5 | |||||||||||||||||
Return Loss | dB | ≥55/50 | |||||||||||||||||
Directivity | dB | ≥55 |
2×N PLC Splitter
Parameter | Unit | Value | |||||||
Product Type | 2×2 | 2×4 | 2×8 | 2×16 | 2×32 | 2×64 | 2×128 | ||
Operation Wavelength | nm | 1260~1650 | |||||||
Insertion Loss | Typ. | dB | 4.2 | 7.2 | 10.6 | 13.8 | 17.0 | 20.5 | 24.8 |
Max. | 4.5 | 7.7 | 11.0 | 14.8 | 17.9 | 21.5 | 25.8 | ||
Uniformity (Max.) | dB | 0.8 | 1.0 | 1.2 | 1.5 | 1.8 | 2.5 | 3.0 | |
PDL(Max.) | dB | 0.2 | 0.3 | 0.3 | 0.3 | 0.3 | 0.5 | 1.0 | |
TDL(Max.) | dB | 0.5 | |||||||
Return Loss | dB | ≥55/50 | |||||||
Directivity | dB | ≥55 |
Note: All the data above does not include connectors.
UPC Connectors: IL add 0.2 dB, APC Connectors: IL add 0.3 dB.
Pack information
Split ratio | 1x2 | 1x4 | 1x8 | 1x16 | 1x32 | 1x64 | 1x128 |
Mini-Module Dimension (mm) | 60*7*4 | 60*7*4 | 60*7*4 | 60*12*4 | 80*20*6 | 100*40*6 | N/A |
Steel tube size for 1x8 PLC splitter
Environmental Conditions
Operating Temperature | ℃ | -40~+85 |
Storage Temperature | ℃ | -40~+85 |
Operating Humidity | %RH | ≤93 |
Storage Humidity | %RH | ≤93 |
Ordering Information
PLCS | - | - | - | - | - | - | - |
Structure | Fiber Type | Package | Input | Output | Length | Connector | |
Structure | 0101=1x1, 0202=2x2, ..., 0164=1x64, 0264=2x64 | ||||||
Fiber Type | 1=G652D, 2=G657A1, 3=G657A2 | ||||||
Package Dimension | A1, A2,...A12, D, E, F, K, U, G, C, T, R, X | ||||||
Input Type | B=250μm Bare Fiber ,L=900µm Loose tube, S=2.0mm, R=3.0mm, 0=Adapter | ||||||
Output Type | B=250μm Bare Fiber , L=900µm Loose tube, S=2.0mm, R=3.0mm, F=splitter, 0=Adapter | ||||||
Pigtail Length | 05=0.5m, 10=1.0m, 100=100m, 0=Adapter, 15/10=1.5m input/1.0m output, X=Others | ||||||
Connector Type | FU=FC/UPC, FA=FC/APC, SU=SC/UPC, SA=SC/APC, ST=ST/UPC, LU=LC/UPC, LA=LC/APC, MPA=MPO/APC, FU/FA=FC/UPC input / FC/APC output, 00=None, X=Others |