Inductively Coupled Plasma Optical Emission Spectrometer ICP-6810


ICP-6810 is a full-spectrum direct-reading inductively coupled plasma emission spectrometer for the determination of trace and trace elements in different substances (dissolved in nitric acid, hydrochloric acid, hydrofluoric acid, etc.).

It is widely used in environmental protection, petroleum products, rare earth, semiconductor, geology, metallurgy, chemical industry, clinical medicine, food, biological samples, criminal science, agricultural research and other fields.



Performance characteristics


Performance stability

The use of all-solid-state rf power supply, with small size, high efficiency, stable output power, with a variety of protection functions and many other advantages, the load using fully automatic matching technology, matching speed, improve the efficiency of the use of power supply and the stability of the instrument, and make the whole ignition process simple and convenient.


Injection automation

Adopting four-channel automatic design, the rotational speed can be set up according to the test demand to adjust the flow rate, carrier gas, plasma gas, auxiliary gas are all controlled by advanced mass flow controller, at the same time can be equipped with imported high salt nebulizer, imported hydrofluoric nebulizer and so on to meet the customer's various test needs.


Precision analysis

The middle step grating prism cross dispersion mode is adopted, there is no moving optical element, the ultra low stray light design is combined with the unique optical design, nitrogen distributed blowing, imported optical elements, intelligent and accurate automatic wavelength calibration algorithm.


Quick test

In American thermoelectric CID detector, the 160-1000nm range is continuously covered, and the intensity integral values of all analytical spectral lines are read out at one exposure to speed up the analysis.


Technical parameters of the instrument

  • Output power: 800 -1500W
  • Total argon consumption:≤14L/min
  • Wavelength range:160nm - 1000 nm
  • Resolution: < 0.0065nm@200nm

Instrument technical index

  • Method of observation: vertical observation
  • Liquid content:0.01ppm~thousands of ppm.
  • Solid content:0.001%~70%
  • Repeatability: RSD < 1%
  • Stability: RSD <1.5%(within 2 hours)
  • Element detection limit (μg/L): most elements 1ppb~10ppb


RFPower technical parameter


ircuit type

solid-state RF Power supply, with function of automatch

Frequercy

27.12MHz±0.05%

Frequency Stablity

<0.1%

Power Output

800W-1500W

Power Output Stability

<0.3%

Escaped RF radiation

30cm away from the instrument, electric fiekd: E<2Vtm


Sampling System Technical Parameter


Output working coil imer diameter

25mm

Torpue tube

Three concentric, extemal diameter 20mm

Coaxial nebulizer

Outer dameter 6mm

Double barrel atomizing chamber

Outer diameter 34mm


Gas Flow Controls


Plasma Argon Flowmeter

(100-1000)L/h(1.6-16L/min)

Auxiliary Argon Fiowmeter

(100-1000)L/h(0.16-1.6L/min)

Auxiliary Carrier Argon Flowmeter

(100-1000)L/h(0.16-1.6L/min)

Pressune Maintaining Value

(0-0.4MPa)

Cooling Water:Temperature

20-25℃,Rate of Flow>5L/min,Hydraulic Pressure>0.1MPa


Technical index of spectrometer


Grating

Midde step grating, 52.67 lp/mm, 64 sparkle angle

Wavelength range

160-1000 nm

Numerical aperture

F≤8, ultra-high luminous flux to ensure the detection limit and sensitivity of the instrument

Resolution

< 0.0065nm@200nm

Astigmatism

Equivalent background concentration of 10000 ppm Ca solution at As 189.042 nm <2 ppm

Light chamber

Precision constant temperature, 35±0.1℃, Distributed nitrogen punging, normal purging 1.8L/min, fast purging 3.8L/min


Testing device technical specifications


Detector

CID

Target Size

27.6mm x27.6mm, 1024x1024 addressing detection units

Reading mode

Non-destructive read (NDRO, full reading (FF) and arbitrary read integral (RAI)





Application Field


Inductively coupled plasma emission spectrometer(ICP6800) developed by Macylab Instruments with many years of technology accumulation. It is used to measure traces and traces of various substances (dissolvable in hydrochloric acid, nitric acid, hydrofluoric acid, etc.),and the content of metal elements or non-metallic elements. It is stable and reliable and with high degree of automation and easy operation.
At present, instruments are widely applied in various fields such as rare earth, geology, metallurgy, chemical industry, environmental protection, clinical medicine, petroleum products, semiconductor, food, biological samples, criminal science, agricultural research and so on.

China Laboratory Inductively Coupled Plasma Optical Emission Spectrometer For Hf Solution with CID detector supplier

Laboratory Inductively Coupled Plasma Optical Emission Spectrometer For Hf Solution with CID detector