1600w Icp Plasma Emission Spectrometer Direct Read

Brand Name:Macylab
Certification:ALL OF MADE IN CHINA
Model Number:ICP6810
Minimum Order Quantity:1
Delivery Time:Within 5 days
Payment Terms:L/C, T/T, Western Union, MoneyGram
Contact Now

Add to Cart

Active Member
Location: Beijing Beijing China
Address: A-711, Haige International Building, Xuanwumen, Xicheng District, Beijing China
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

ICP6810 in the nonferrous gold industry

The ICP6810 profile is introduced

The ICP6810 full-spectrum direct-read inductance-coupled plasma emission spectrometer, with excellent resolution, test accuracy and precision, is widely used in the rare earth industry, chemical industry, andOre analysis, metal smelting, geological research, drug safety, experimental research, environmental testing, food safety and other industries.Especially for the determination of elements in the ICP6810 zinc oxide industry.

picture1.ICP6810


Table 1. Main technical parameters of ICP6810

ICP6810 main technical parameters

High frequency ionizer
Working frequency27.12MHz
Frequency stability﹤0.05%
Output power800W ~1600W
Output power stability≤0.05%
OMatching wayAutomatic matching
Scan the light divider
light pathFull reflection imaging light path, quartz prism two-dimensional dispersion system
focal distance400mm
Graster specificationsMiddle step grating, 52.67, l p / mm, 64 shining angle
Resolution ratio<0.0068nm@200nm
Complete machine technical indicators
Scan the wavelength rangeAt 165-900nm, full wavelength coverage, and measurable Al 167.120nm
RepetitivenessRSD≤1.5%
StabilityRSD≤2.0%

ICP6810 element detection limit (g / L)

elementLaCePrNdSmEuGdTb
wavelength (nm)408.672413.765414.311401.225360.946381.967342.247350.917
detection limit<3.0<5.0<5.0<5.0<10.0<1.0<10.0<3.0

elementDyHoErTmYbLuYSc
wavelength (nm)353.170345.600337.271313.126369.419261.541371.030335.373
detection limit<3.0<3.0<3.0<3.0<1.0<3.0<1.0<1.0

elementTaNbMnMgBZnCoSi
wavelength (nm)226.230313.340257.610279.553249.773213.856228.616251.611
detection limit<5.0<5.0<3.0<1.0<10.0<3.0<3.0<10.0

elementNiCdFeCaMoVBeTi
wavelength (nm)232.003226.502239.562393.366281.615310.230313.041334.941
detection limit<5.0<3.0<3.0<1.0<5.0<5.0<1.0<3.0

elementCuCrAlZrAgSrAuPt
wavelength (nm)324.754267.716396.152343.823328.068407.771242.795265.945
detection limit<3.0<5.0<5.0<5.0<3.0<1.0<5.0<5.0

elementPdIrRhRuBaLiNaK
wavelength (nm)340.458224.268343.489240.272455.403670.784588.995766.490
detection limit<5.0<10.0<10.0<5.0<1.0≤3≤20≤60

elementAsSbBiHgPbGaOsW
wavelength (nm)228.812206.833223.061253.652220.353294.364225.585207.911
detection limit≤15≤15≤10≤15≤15≤10≤1≤10

elementSnTeTaThTlReGeSe
wavelength (nm)242.949214.281226.230283.730276.787227.525209.426203.985
detection limit≤20≤10≤5.0≤10≤30≤5≤15≤30

●Evaluation of alloy measurable elements in non-ferrous precious metals

For precious metal samples and customer test requirements, the details are shown in the Table:

2. Precious metal sample test solution

samplemeasureelementAnalysis instrumentSample handling overview (for reference only)remarks
Non-ferrous precious metal alloyGold, silver, palladium, platinum, and so onICP6810Take 0.1-0.3g sample in a 100ml beaker, add 5ml hydrochloric acid, dissolve the sample on the heating plate to clarification, remove cold to room temperature, transferred to 50ml volumetric flask diluted with water to scale for testing.Sample blank experiment was also performed simultaneously duringthesampleprocessing process.

According to the configured standard solution concentration, directly on the computer test, the instrument can automatically give the final test results, and can be directly printed in the form of a report.

Table 3.ICP6810 and related instrument configuration

Instrument host and necessary accessories
order numberdefinitionSpecifications / modelsmanufacturerquantity remarksquantity remarks
1Full-spectrum straight-read inductively coupled plasma emission spectrometerICP6810Shanghai Beauty Instrument Co., Ltd1 
2Automatic temperature control and circulating cooling water device1 
3stabilized voltage supply1 
Instrument matching accessories
order numberdefinitionSpecifications / modelsmanufacturerquantity remarksquantity remarks
1host1 
2graphoscope1 
3marking punch1 
Sample processing equipment and consumables
order numberdefinitionSpecifications / modelsmanufacturerquantity remarksquantity remarks
1Electronictemperature-controlled heating boardEG-35B1 
2One in ten thousand is an electronic balanceBS224S1 
3Laboratory-grade ultra-pure water machineEPED-40T1 
4Disposable rubber GlovesM / 
5Activated carbon mask  / 
63mlpasteurpipette3ml / 
7100mlglass beaker100mlSichuan Shu Glass scientific Instruments/ 
8100mlGlass capacity bottle100mlSichuan Shu Glass scientific Instruments/ 
95mltransfer liquid gun0.5ml-5mlRand, Germany1 
101mltransfer liquid gun100ul-1000ulRand, Germany1 
Reagent
order numberdefinitionSpecifications / modelsmanufacturerquantity remarksquantity remarks
1hydrochloric acid GR Jiangsu Qiangsheng Chemical Co., Ltdhydrochloric acid GR Jiangsu Qiangsheng Chemical Co., Ltdhydrochloric acid GR Jiangsu Qiangsheng Chemical Co., Ltd/ 
2hydrogen nitrate GR Jiangsu Qiangsheng Chemical Co., Ltdhydrogen nitrate GR Jiangsu Qiangsheng Chemical Co., Ltdhydrogen nitrate GR Jiangsu Qiangsheng Chemical Co., Ltd/ 
3perhydrol GR Jiangsu Qiangsheng Chemical Co., Ltdperhydrol GR Jiangsu Qiangsheng Chemical Co., Ltdperhydrol GR Jiangsu Qiangsheng Chemical Co., Ltd/
4Standard material of each element 1000ug/ml National nonferrous Metals and electronic materials center of forecasting and analysisStandard material of each element 1000ug/ml National nonferrous Metals and electronic materials center of forecasting and analysisStandard material of each element 1000ug/ml National nonferrous Metals and electronic materials center of forecasting and analysis/ 

If you have any other questions, please call the analysis instrument